Literature DB >> 11220280

[Accommodative lens implant].

P R Preussner1, J Wahl, R Gerl, C Kreiner, A Serester.   

Abstract

PROBLEM: To date, approaches to restore accommodation following cataract surgery have been based on the principle of a liquid or solid implant that moves within the capsular bag and thereby changes the optical characteristics of the eye. However, these implants have been associated with shrinking and fibrosis of the capsular bag, a problem that will not be solved in the foreseeable future. APPROACH: If accommodation is effected by shifting the whole capsule including its contents on the optical axis, capsular fibrosis will virtually no longer play a role. In order to execute this shift via the neuronal feedback mechanisms of the ciliary muscle in a controlled way, radial zonular forces or movements must be transformed into axial ones, which is possible by means of tiny permanent magnets. This paper describes the basic aspects of such an implant. The dependence of accommodation on all relevant parameters is quantified in a computer simulation.
CONCLUSION: The implant described appears to be practicable with justifiable technical and surgical efforts.

Entities:  

Mesh:

Year:  2001        PMID: 11220280     DOI: 10.1007/s003470170208

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  6 in total

Review 1.  Accommodating intraocular lenses: a critical review of present and future concepts.

Authors:  R Menapace; O Findl; K Kriechbaum; Ch Leydolt-Koeppl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-30       Impact factor: 3.117

2.  [Triple-optic approach to the Artificial Accommodation System].

Authors:  M Bergemann; I Sieber; G Bretthauer; R F Guthoff
Journal:  Ophthalmologe       Date:  2007-04       Impact factor: 1.059

Review 3.  [Accommodation and presbyopia : part 2: surgical procedures for the correction of presbyopia].

Authors:  M Baumeister; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

Review 4.  Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: optical performance and clinical outcomes.

Authors:  Javier Tomás-Juan; Ane Murueta-Goyena Larrañaga
Journal:  J Optom       Date:  2014-09-22

5.  Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens.

Authors:  Hanka Schneider; Oliver Stachs; Katja Göbel; Rudolf Guthoff
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-17       Impact factor: 3.117

Review 6.  Posterior capsulorhexis combined with optic buttonholing: an alternative to standard in-the-bag implantation of sharp-edged intraocular lenses? A critical analysis of 1000 consecutive cases.

Authors:  R Menapace
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-04-19       Impact factor: 3.117

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.