Literature DB >> 11219053

Simultaneous quantitative determination of norgestrel and progesterone in human serum by high-performance liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization.

Z Wu1, C Zhang, C Yang, X Zhang, E Wu.   

Abstract

A selective, reliable and rapid method for the simultaneous determination of progesterone and norgestrel concentrations in human serum after taking oral contraceptive tablet has been developed using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with atmospheric pressure chemical ionization (APCI) interface. The norethisterone was used as the internal standard. Selected transitions of m/z 313/245 for norgestrel, m/z 315/97 for progesterone and m/z 299/109 for norethisterone were monitored using multiple reaction monitoring (MRM) mode for quantitation. The assay was linear over the concentration range of 0.2-50 ng mL-1 for norgestrel and progesterone. The lower level of quantitation in human serum was obtained at 0.2 ng mL-1 for both norgestrel and progesterone using optimum tuning parameters. The intra-assay precision and inter-assay precision do not exceed 10 and 9%, respectively. The method has been applied to the determination of norgestrel and progesterone in serum of female volunteers.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11219053     DOI: 10.1039/b005631f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  In vivo absorption of steroidal hormones from smart polymer based delivery systems.

Authors:  Sibao Chen; Daniel Pederson; Mayura Oak; Jagdish Singh
Journal:  J Pharm Sci       Date:  2010-08       Impact factor: 3.534

2.  Steroid hormone levels in pregnancy and 1 year postpartum using isotope dilution tandem mass spectrometry.

Authors:  Offie P Soldin; Tiedong Guo; Elisabete Weiderpass; Rochelle E Tractenberg; Leena Hilakivi-Clarke; Steven J Soldin
Journal:  Fertil Steril       Date:  2005-09       Impact factor: 7.329

3.  Tb3+-atorvastatin doped in poly(ethylene glycol) optical biosensor for selective determination of progesterone and testosterone in serum samples.

Authors:  Mohamed S Attia; Safwat A Mahmoud; Amal M Ahmed; Tarek A Amin; Ahmed O Youssef; Mohammed A Amin; Mona N Abou-Omar; Ekram H Mohamed
Journal:  RSC Adv       Date:  2021-10-12       Impact factor: 4.036

Review 4.  Steroid hormones: relevance and measurement in the clinical laboratory.

Authors:  Jennifer P Holst; Offie P Soldin; Tiedong Guo; Steven J Soldin
Journal:  Clin Lab Med       Date:  2004-03       Impact factor: 1.935

  4 in total