Literature DB >> 11217774

Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine.

Y Deng1, J Henion, J Li, P Thibault, C Wang, D J Harrison.   

Abstract

A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the CE separation and on-line electrospray detection of carnitine and selected acylcarnitines from mixtures of analytical standards as well as extracts of fortified human urine. Chip-based CE/MS experiments in two different laboratories were carried out using a triple-quadrupole mass spectrometer and a quadrupole time-of-flight (QTOF) mass spectrometer, respectively. The glass chips used with both systems were comparably equipped with a microfabricated capillary electrophoresis (CE) channel but with different electrosprayers. The quadrupole chip-based CE/MS experiments employed a miniature coupled microsprayer, which allowed coupling of the microelectrospray process via a micro liquid junction at the exit of the CE capillary channel. Selected ion monitoring (SIM) CE/MS experiments were employed for all of the quadrupole CE/MS work. The QTOF CE/MS full-scan single MS and MS/MS experiments were carried out in another laboratory using accurate mass measurement TOF mass spectrometry techniques. The electrospray process that was employed with the QTOF system differed in that an inserted nanoelectrospray capillary needle was carefully affixed into a flat-bottomed hole that was aligned with the CE channel exit orifice. SIM CE/MS using the described quadrupole system provided acceptable ion current electropherograms from fmole levels from analytical standard solutions of carnitine and acylcarnitines that were manually injected (loaded) onto the chip. In addition, the corresponding electropherograms for human urine fortified with the target carnitine and acylcarnitines at a 10-20 microg/mL (35-124 microM) level were obtained via SIM CE/MS techniques. The measured CE separation efficiency for the SIM CE/MS electropherograms was determined to be 2860 plates (peak width at half-height method or N = 5.54(T/WO.5(2)), and carnitine and three acylcarnitines were separated in less than 48 s. In contrast, using quadrupole-TOF technologies, the same samples could be diluted by a factor of 2-4 to obtain a comparable detector response for the target compounds. In the full-scan, single mass analyzer mode (m/z 150-500), the CE separation efficiency was measured to be 2600 plates, but mass measurement accuracy was less than 5.0 ppm for the quaternary cations. In the CE/MS/MS mode, full-scan collision-induced dissociation (CID) mass spectra were obtained with a mass accuracy of < or =10 ppm for the higher mass ions and < or =27 ppm for the lower mass product ions. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric detection for these important compounds in synthetic mixtures, as well as in human urine extracts.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11217774     DOI: 10.1021/ac0009346

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Elastomeric microchip electrospray emitter for stable cone-jet mode operation in the nanoflow regime.

Authors:  Ryan T Kelly; Keqi Tang; Daniel Irimia; Mehmet Toner; Richard D Smith
Journal:  Anal Chem       Date:  2008-04-18       Impact factor: 6.986

Review 2.  Generation of mass tags by the inherent electrochemistry of electrospray for protein mass spectrometry.

Authors:  Christophe Roussel; Loïc Dayon; Niels Lion; Tatiana C Rohner; Jacques Josserand; Joël S Rossier; Henrik Jensen; Hubert H Girault
Journal:  J Am Soc Mass Spectrom       Date:  2004-12       Impact factor: 3.109

3.  Fully integrated glass microfluidic device for performing high-efficiency capillary electrophoresis and electrospray ionization mass spectrometry.

Authors:  J S Mellors; V Gorbounov; R S Ramsey; J M Ramsey
Journal:  Anal Chem       Date:  2008-08-13       Impact factor: 6.986

4.  Graphene-based biomimetic materials targeting urine metabolite as potential cancer biomarker: application over different conductive materials for potentiometric transduction.

Authors:  Liliana A A N A Truta; Nádia S Ferreira; M Goreti F Sales
Journal:  Electrochim Acta       Date:  2014-12-20       Impact factor: 6.901

5.  Determination of L-Carnitine in Infant Powdered Milk Samples after Derivatization.

Authors:  Jung Min Park; Jong Ho Koh; Jin Man Kim
Journal:  Food Sci Anim Resour       Date:  2021-07-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.