Literature DB >> 11216537

Automated stereotactic standardization of brain SPECT receptor data using single-photon transmission images.

K Van Laere1, M Koole, Y D'Asseler, J Versijpt, K Audenaert, F Dumont, R Dierckx.   

Abstract

UNLABELLED: Intra- or intersubject registration of anatomically poorly defined SPECT data, such as in neuroreceptor imaging, is important for longitudinal or group analysis. However, accurate registration is difficult with only emission CT (ECT) data. We investigated fully automated registration using transmission CT (TCT) data as an intermediary image set.
METHODS: The accuracy of TCT registration was compared to that of ECT registration for four types of data: gray-matter distribution (with [99mTc]ethylcysteinate dimer (ECD)), neocortical distribution (with [123I]R91150, a highly specific 5-HT2a receptor ligand), and striatal distribution of the D2-receptor ligand (with [123I]iodobenzamide (IBZM)) and the dopamine transporter ligand (with [123I]2beta-carbomethoxy-3beta-(4-fluorophenyl)tropane (CIT)). In total, 10 datasets of the various study types were used, all collected on a Toshiba GCA9300 gamma camera with super-high-resolution fanbeam collimators and 3 x 370 MBq of 153Gd transmission sources (4-min sequential TCT scanning for receptor studies and 20-min simultaneous scanning for [99mTc]ECD studies). Per dataset, 15 random misalignments of 9 rigid-body parameters (translation, rotation, and anisotropic scaling) were conducted. All coregistrations were done twice, both to the subject's original scan and to a study-specific template. This was done manually by two independent experienced observers and with three automated voxel similarity algorithms: mutual information (M.I.), count difference (C.D.), and uniformity index (U.I.). As an outcome measure, the impact of misregistration on semiquantification for the various study types was established.
RESULTS: TCT matching allowed registration within 3.3 mm, 2.4 degrees, and 1.2% scaling (mean squared values for all directions) with an overall accuracy decrease in the following order: C.D. > M.I. > manual > U.I. For [99mTc]ECD and [123I]IBZM, TCT registration was as accurate as ECT registration, while it was far superior for the other receptor data types, especially for abnormal studies. The automated TCT registration accuracy corresponded to average quantification errors of 2.9% ([99mTc]ECD), 4.2% ([123I]BZM), 5.7% ([123I]R91150), and 6.1% ([123I]beta-CIT).
CONCLUSION: Fully automated registration through intermediary TCT images is clinically feasible, fast, and accurate. In addition to nonuniform attenuation correction, TCT scanning therefore allows coregistration for group comparisons of SPECT receptor data on a standardized or pixel-by-pixel basis.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11216537

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

1.  Registration accuracy of 153Gd transmission images of the brain.

Authors:  F Jacobs; M Koole; I Goethals; C Van de Wiele; H Ham; R Dierckx
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-06       Impact factor: 9.236

Review 2.  A review on the clinical uses of SPECT/CT.

Authors:  Giuliano Mariani; Laura Bruselli; Torsten Kuwert; Edmund E Kim; Albert Flotats; Ora Israel; Maurizio Dondi; Naoyuki Watanabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-02-25       Impact factor: 9.236

3.  Interpolation-based super-resolution reconstruction: effects of slice thickness.

Authors:  Amir Pasha Mahmoudzadeh; Nasser H Kashou
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-25

4.  IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies.

Authors:  Ralph Buchert; Georg Berding; Florian Wilke; Brigitte Martin; Daniel von Borczyskowski; Janos Mester; Winfried Brenner; Malte Clausen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-14       Impact factor: 9.236

5.  Evaluation of interpolation effects on upsampling and accuracy of cost functions-based optimized automatic image registration.

Authors:  Amir Pasha Mahmoudzadeh; Nasser H Kashou
Journal:  Int J Biomed Imaging       Date:  2013-08-01

6.  A standardized method for the construction of tracer specific PET and SPECT rat brain templates: validation and implementation of a toolbox.

Authors:  David Vállez Garcia; Cindy Casteels; Adam J Schwarz; Rudi A J O Dierckx; Michel Koole; Janine Doorduin
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240

7.  The basal ganglia matching tools package for striatal uptake semi-quantification: description and validation.

Authors:  Piero Calvini; Guido Rodriguez; Fabrizio Inguglia; Alessandro Mignone; Ugo Paolo Guerra; Flavio Nobili
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-08       Impact factor: 10.057

8.  Hostility in medication-resistant major depression and comorbid generalized anxiety disorder is related to increased hippocampal-amygdala 5-HT2A receptor density.

Authors:  Chris Baeken; Yanfeng Xu; Guo-Rong Wu; Robrecht Dockx; Kathelijne Peremans; Rudi De Raedt
Journal:  Eur Arch Psychiatry Clin Neurosci       Date:  2021-04-27       Impact factor: 5.270

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.