A high-performance liquid chromatographic method with a dynamically modified amino column and evaporative light-scattering detector (ELSD) was established for the direct analysis of the carbohydrates in some drinks. A separation column (Zorbax Rx-SIL, 250 mm x 4.6 mm I.D., 5 microm, Hewlett-Packard, USA) which was modified by ethylenediamine and a guard column (Zorbax Rx-SIL, 12.5 mm x 4.6 mm I.D., 5 microm) were used. The mobile phase was a mixture of water-acetonitrile (1:2.6, v/v) containing 0.03% (v/v) ethylenediamine. Regression equations revealed linear relationship (correlation coefficients=0.996-0.999) between the mass of carbohydrates injected and the carbohydrates peak areas detected by ELSD. The detection limits of ELSD (S/N=3) were between 0.2 and 1.2 microg for different carbohydrates. This method is simple and sensitive.Entities:
Mesh:
Substances:
Year: 2000 PMID: 11209897 DOI: 10.1016/s0021-9673(00)00909-2