Literature DB >> 11207747

Legionella: from environmental habitats to disease pathology, detection and control.

R M Atlas1.   

Abstract

Studies on Legionella show a continuum from environment to human disease. Legionellosis is caused by Legionella species acquired from environmental sources, principally water sources such as cooling towers, where Legionella grows intracellularly in protozoa within biofilms. Aquatic biofilms, which are widespread not only in nature, but also in medical and dental devices, are ecological niches in which Legionella survives and proliferates and the ultimate sources to which outbreaks of legionellosis can be traced. Invasion and intracellular replication of L. pneumophila within protozoa in the environment play a major role in the transmission of Legionnaires' disease. Protozoa provide the habitats for the environmental survival and reproduction of Legionella species. L. pneumophila proliferates intracellularly in various species of protozoa within vacuoles studded with ribosomes, as it also does within macrophages. Growth within protozoa enhances the environmental survival capability and the pathogenicity (virulence) of Legionella. The growth requirements of Legionella, the ability of Legionella to enter a viable non-culturable state, the association of Legionella with protozoa and the occurrence of Legionella within biofilms complicates the detection of Legionella and epidemiological investigations of legionellosis. Polymerase chain reaction (PCR) methods have been developed for the molecular detection of Legionella and used in environmental and epidemiological studies. Various physical and chemical disinfection methods have been developed to eliminate Legionella from environmental sources, but gaining control of Legionella in environmental waters, where they are protected from disinfection by growing within protozoa and biofilms, remains a challenge, and one that must be overcome in order to eliminate sporadic outbreaks of legionellosis.

Entities:  

Mesh:

Year:  1999        PMID: 11207747     DOI: 10.1046/j.1462-2920.1999.00046.x

Source DB:  PubMed          Journal:  Environ Microbiol        ISSN: 1462-2912            Impact factor:   5.491


  58 in total

1.  Biofilms: A Clinical Perspective.

Authors:  Michael Bell
Journal:  Curr Infect Dis Rep       Date:  2001-12       Impact factor: 3.725

2.  High-resolution in situ genotyping of Legionella pneumophila populations in drinking water by multiple-locus variable-number tandem-repeat analysis using environmental DNA.

Authors:  Leila Kahlisch; Karsten Henne; Josefin Draheim; Ingrid Brettar; Manfred G Höfle
Journal:  Appl Environ Microbiol       Date:  2010-07-23       Impact factor: 4.792

3.  Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay.

Authors:  Severine Allegra; Florence Grattard; Françoise Girardot; Serge Riffard; Bruno Pozzetto; Philippe Berthelot
Journal:  Appl Environ Microbiol       Date:  2010-12-23       Impact factor: 4.792

4.  Enumeration of Legionella pneumophila in cooling tower water systems.

Authors:  Irfan Türetgen; Esra Ilhan Sungur; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2005-01       Impact factor: 2.513

5.  Legionella contamination in hot water of Italian hotels.

Authors:  Paola Borella; Maria Teresa Montagna; Serena Stampi; Giovanna Stancanelli; Vincenzo Romano-Spica; Maria Triassi; Isabella Marchesi; Annalisa Bargellini; Daniela Tatò; Christian Napoli; Franca Zanetti; Erica Leoni; Matteo Moro; Stefania Scaltriti; Gabriella Ribera D'Alcalà; Rosalba Santarpia; Stefania Boccia
Journal:  Appl Environ Microbiol       Date:  2005-10       Impact factor: 4.792

6.  Legionella confirmation using real-time PCR and SYTO9 is an alternative to current methodology.

Authors:  Steven Giglio; Paul T Monis; Christopher P Saint
Journal:  Appl Environ Microbiol       Date:  2005-12       Impact factor: 4.792

7.  Microbial contamination of dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay; Ayşin Cotuk; Zuhal Zeybek
Journal:  Environ Monit Assess       Date:  2008-01-22       Impact factor: 2.513

8.  Use of flow cytometry to monitor Legionella viability.

Authors:  Séverine Allegra; Françoise Berger; Philippe Berthelot; Florence Grattard; Bruno Pozzetto; Serge Riffard
Journal:  Appl Environ Microbiol       Date:  2008-10-10       Impact factor: 4.792

9.  Role of bacterial adhesion in the microbial ecology of biofilms in cooling tower systems.

Authors:  Yang Liu; Wei Zhang; Tadas Sileika; Richard Warta; Nicholas P Cianciotto; Aaron Packman
Journal:  Biofouling       Date:  2009       Impact factor: 3.209

10.  Legionella pneumophila serogroup 1 strain Paris: endemic distribution throughout France.

Authors:  Helena Aurell; Jerome Etienne; Françoise Forey; Monique Reyrolle; Pascale Girardo; Pierre Farge; Bénédicte Decludt; Christine Campese; François Vandenesch; Sophie Jarraud
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.