Literature DB >> 11204544

Biomechanical and morphometric properties of the arterial wall referenced to the zero-stress state in experimental diabetes.

J Zhao1, X Lu, F Zhuang, H Gregersen.   

Abstract

Morphometric and passive biomechanical properties were studied in isolated segments of the thoracic and abdominal aorta, left common carotid artery, left femoral artery and the left pulmonary artery in 20 non-diabetic and 28 streptozotocin (STZ)-induced diabetic rats. The diabetic and non-diabetic rats were divided into groups living 1, 4, 8, and 12 weeks after the induction of diabetes (n = 7 for each diabetic group) or sham injection (n = 5 for each group). The mechanical test was performed as a distension experiment where the proximal end of the arterial segment was connected via a tube to the container used for applying pressures to the segment and the distal end was left free. The vessel diameter and length were obtained from digitized images of the arterial segments at pre-selected pressures and at no-load and zero-stress states. Circumferential and longitudinal stresses (force per area) and strains (deformation) were computed from the length, diameter and pressure data and from the zero-stress state data. The zero-stress state was obtained by cutting vessel rings radially causing the rings to open up into a sector. Diabetes was associated with pronounced morphometric changes, e.g., wall thickness. With respect to the biomechanical data, the opening angle increased and reached a plateau in 4 weeks after which it decreased again (p < 0.05). The opening angle was smallest in the thoracic aorta and largest in the pulmonary artery. Furthermore, it was found that the circumferential stiffness of the arteries studied increased with the duration of diabetes. In the longitudinal direction significant differences were found 8 weeks after injection of STZ in all arteries except the pulmonary artery. In the 12 weeks group, the femoral artery was stiffest in the circumferential direction whereas the thoracic aorta was stiffest in the longitudinal direction. The accumulated serum glucose level correlated with the arterial wall thickness and elastic modulus (correlation coefficient between 0.56 and 0.81).

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11204544

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  4 in total

1.  Rosiglitazone reverses endothelial dysfunction but not remodeling of femoral artery in Zucker diabetic fatty rats.

Authors:  Xiao Lu; Xiaomei Guo; Sotirios K Karathanasis; Karen M Zimmerman; Jude E Onyia; Richard G Peterson; Ghassan S Kassab
Journal:  Cardiovasc Diabetol       Date:  2010-05-19       Impact factor: 9.951

2.  Morphologic and biomechanical changes of rat oesophagus in experimental diabetes.

Authors:  Yan-Jun Zeng; Jian Yang; Jing-Bo Zhao; Dong-Hua Liao; En-Ping Zhang; Hans Gregersen; Xiao-Hu Xu; Hong Xu; Chuan-Qing Xu
Journal:  World J Gastroenterol       Date:  2004-09-01       Impact factor: 5.742

3.  Angiotensin II receptor blocker telmisartan attenuates aortic stiffening and remodelling in STZ-diabetic rats.

Authors:  Erik Salum; Mark Butlin; Jaak Kals; Mihkel Zilmer; Jaan Eha; Alberto P Avolio; Andres Arend; Marina Aunapuu; Priit Kampus
Journal:  Diabetol Metab Syndr       Date:  2014-05-20       Impact factor: 3.320

4.  Failure Properties of Healthy and Diabetic Rabbit Thoracic Aortas and Their Potential Correlation with Mass Fractions of Collagen.

Authors:  J Tong; X Xu; Y F Xin; Z Zhang; C H Wu
Journal:  Cardiovasc Eng Technol       Date:  2021-06-17       Impact factor: 2.495

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.