Literature DB >> 11203820

Rigidity and retention of ceramic root canal posts.

D G Purton1, R M Love, N P Chandler.   

Abstract

Ceramic root-canal posts offer potential advantages over other types with respect to aesthetics and biocompatibility. Any post must be sufficiently rigid and retentive to withstand functional forces. Ceraposts (1.2 mm coronal diameter, ceramic, tapering, smooth posts) and Paraposts (1.25 mm, stainless-steel, parallel, serrated posts) were tested for rigidity by means of a three-point bending test. To test retention in roots, ceramic posts were cemented using one of three protocols: (1) glass-ionomer cement, (2) silane coupling agent and resin cement, or (3) sandblasted post surface, silane coupling agent, and resin cement. Stainless-steel posts were cemented with resin. The tensile force required to dislodge the posts, following four weeks of storage in water, was recorded. Data were compared using Student's t-test and Mann-Whitney U analysis. Ceraposts were significantly more rigid than Paraposts (p < 0.001). Paraposts cemented with resin were significantly more strongly retained than Ceraposts following any cementation protocol (p < 0.001). Retention of the ceramic posts was significantly greater with a silane coupling agent and resin cement than with glass-ionomer cement (p < 0.001). Sandblasting the ceramic posts produced variable results and needs further investigation before it could be recommended.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11203820

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  4 in total

1.  Effect of Er,Cr:YSGG pretreatment on bond strength of fiber posts to root canal dentin using a self-adhesive resin cement.

Authors:  Narmin Mohammadi; Siavash Savadi Oskoee; Mehdi Abed Kahnamoui; Mahmoud Bahari; Soodabeh Kimyai; Sahand Rikhtegaran
Journal:  Lasers Med Sci       Date:  2012-02-28       Impact factor: 3.161

2.  Influence of laser irradiation on fiber post retention.

Authors:  Denis Y Nagase; Patricia M de Freitas; Susana Morimoto; Margareth Oda; Glauco F Vieira
Journal:  Lasers Med Sci       Date:  2010-12-03       Impact factor: 3.161

3.  A comparative evaluation of the fracture resistance of three different pre-fabricated posts in endodontically treated teeth: An in vitro study.

Authors:  Prabeesh Padmanabhan
Journal:  J Conserv Dent       Date:  2010-07

Review 4.  Revolution of Current Dental Zirconia: A Comprehensive Review.

Authors:  Ahmed Yaseen Alqutaibi; Omar Ghulam; Majid Krsoum; Suhail Binmahmoud; Hasan Taher; Wael Elmalky; Muhammad Sohail Zafar
Journal:  Molecules       Date:  2022-03-04       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.