Literature DB >> 11203643

A comparison of laser-welded titanium and conventional cast frameworks supported by implants in the partially edentulous jaw: a 3-year prospective multicenter study.

T Jemt1, P Henry, B Lindén, I Naert, H Weber, C Bergström.   

Abstract

PURPOSE: The purpose of this prospective multicenter study was to evaluate and compare the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with conventional cast frameworks.
MATERIALS AND METHODS: Forty-two partially edentulous patients were provided with Brånemark system implants and arranged into 2 groups. Group A was provided with a conventional cast framework with porcelain veneers in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain on the other side. The patients in group B had an old implant prosthesis replaced by a titanium framework prosthesis. The patients were followed for 3 years after prosthesis placement. Clinical and radiographic data were collected and analyzed.
RESULTS: Only one implant was lost, and all prostheses were still in function after 3 years. The 2 framework designs showed similar clinical performance with few clinical complications. Only one abutment screw (1%) and 9 porcelain tooth units (5%) fractured. Four prostheses experienced loose gold screws (6%). In group A, marginal bone loss was similar for both designs of prostheses, with a mean of 1.0 mm and 0.3 mm in the maxilla and mandible, respectively. No bone loss was observed on average in group B. No significant relationship (P > 0.05) was observed between marginal bone loss and placement of prosthesis margin or prosthesis design.
CONCLUSION: The use of laser-welded titanium frameworks seems to present similar clinical performance to conventional cast frameworks in partial implant situations after 3 years.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11203643

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  4 in total

Review 1.  WITHDRAWN: Interventions for replacing missing teeth: partially absent dentition.

Authors:  Elliot Abt; Alan B Carr; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-07-17

2.  Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study.

Authors:  Yeon-Hee Park; Kyoung-A Kim; Jung-Jin Lee; Tae-Min Kwon; Jae-Min Seo
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

Review 3.  Applications of Laser Welding in Dentistry: A State-of-the-Art Review.

Authors:  Asma Perveen; Carlo Molardi; Carlo Fornaini
Journal:  Micromachines (Basel)       Date:  2018-04-28       Impact factor: 2.891

4.  Influence of Filler Metal on Electrochemical Characteristics of a Laser-Welded CoCrMoW Alloy Used in Prosthodontics.

Authors:  Lukasz Reimann; Zbigniew Brytan; Grzegorz Jania
Journal:  Materials (Basel)       Date:  2022-08-19       Impact factor: 3.748

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.