Literature DB >> 11203604

Two-unit cantilevered resin-bonded fixed partial dentures--a retrospective, preliminary clinical investigation.

M G Botelho1, L C Nor, H W Kwong, B S Kuen.   

Abstract

PURPOSE: The aim of this study was to retrospectively evaluate the clinical retention and abutment movement of 2-unit cantilevered resin-bonded fixed partial dentures (FPD) that were inserted at Prince Philip Dental Hospital in Hong Kong.
MATERIALS AND METHODS: Of 45 patients who were identified from a hospital computer search after receiving a 2-unit cantilevered resin-bonded FPD, 31 were clinically examined (33 FPDs). For each patient the following data were recorded: gender, age, cementation date, endodontic treatment if performed, bone support, tooth mobility, and FPD tipping or drifting. Data about any debonds with subsequent treatment and patient satisfaction on a 10-point scale were also recorded.
RESULTS: The mean service life for the 33 prostheses was 30 +/- 18 months, with a range of 72 days to 67 months. One prosthesis debonded, resulting in a clinical retention rate of 97%. No rotation, drifting, or tipping was observed for any of the prostheses during the short period of this study.
CONCLUSION: Two-unit cantilevered resin-bonded FPDs are successful in the short term, but further research is required to determine if they offer a viable alternative to fixed-fixed resin-bonded FPD designs.

Entities:  

Mesh:

Year:  2000        PMID: 11203604

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  3 in total

Review 1.  Congenitally missing teeth (hypodontia): A review of the literature concerning the etiology, prevalence, risk factors, patterns and treatment.

Authors:  Vahid Rakhshan
Journal:  Dent Res J (Isfahan)       Date:  2015 Jan-Feb

2.  Resin bonded bridges in patients with hypodontia: Clinical performance over a 7 year observation period.

Authors:  Lamyia Anweigi; Ambreen Azam; Cristiane de Mata; Ebtissam AlMadi; Samar Alsaleh; Alhanoof Aldegheishem
Journal:  Saudi Dent J       Date:  2019-12-11

3.  Comparison of Tensile Bond Strength of Fixed-Fixed Versus Cantilever Single- and Double-Abutted Resin-Bonded Bridges Dental Prosthesis.

Authors:  Shweta Narwani; Naveen S Yadav; Puja Hazari; Vrinda Saxena; Abdulrahman H Alzahrani; Ahmed Alamoudi; Bassam Zidane; Nasreen Hassan Mohammed Albar; Ali Robaian; Sushil Kishnani; Kirti Somkuwar; Shilpa Bhandi; Kumar Chandan Srivastava; Deepti Shrivastava; Shankargouda Patil
Journal:  Materials (Basel)       Date:  2022-08-19       Impact factor: 3.748

  3 in total