Literature DB >> 11203534

Mechanical properties and microstructures of glass-ionomer cements.

D Xie1, W A Brantley, B M Culbertson, G Wang.   

Abstract

OBJECTIVE: The objective of this study was to determine the flexural strength (FS), compressive strength (CS), diametral tensile strength (DTS), Knoop hardness (KHN) and wear resistance of ten commercial glass-ionomer cements (GICs). The fracture surfaces of these cements were examined using scanning electron microscopic (SEM) techniques to ascertain relationships between the mechanical properties and microstructures of these cements.
METHODS: Specimens were fabricated according to the instructions from each manufacturer. The FS, CS, DTS, KHN and wear rate were measured after conditioning the specimens for 7 d in distilled water at 37 degrees C. One-way analysis of variance with the post hoc Tukey-Kramer multiple range test was used to determine which specimen groups were significantly different for each test. The fracture surface of one representative specimen of each GIC from the FS tests was examined using a scanning electron microscope.
RESULTS: The resin-modified GICs (RM GICs) exhibited much higher FS and DTS, not generally higher CS, often lower Knoop hardness and generally lower wear resistance, compared to the conventional GICs (C GICs). Vitremer (3M) had the highest values of FS and DTS; Fuji II LC (GC International) and Ketac-Molar (ESPE) had the highest CS; Ketac-Fil (ESPE) had the highest KHN. Ketac-Bond (ESPE) had the lowest FS; alpha-Silver (DMG-Hamburg) had the lowest CS. Four GICs (alpha-Fil (DMG-Hamburg), alpha-Silver, Ketac-Bond and Fuji II) had the lowest values of DTS, which were not significantly different from each other; alpha-Silver and Ketac-Silver had the lowest values of KHN. The highest wear resistance was exhibited by alpha-Silver and Ketac-Fil; F2LC had the lowest wear resistance. The C GICs exhibited brittle behavior, whereas the RM GICs underwent substantial plastic deformation in compression. The more integrated the microstructure, the higher were the FS and DTS. Higher CS was correlated with smaller glass particles, and higher KHN was found where there was a combination of smaller glass particles and lower porosity. Larger glass particle sizes and a more integrated microstructure contributed to a higher wear resistance. SIGNIFICANCE: The mechanical properties of GICs were closely related to their microstructures. Factors such as the integrity of the interface between the glass particles and the polymer matrix, the particle size, and the number and size of voids have important roles in determining the mechanical properties.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11203534     DOI: 10.1016/s0109-5641(99)00093-7

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  77 in total

1.  Evaluation of fit of cement-retained implant-supported 3-unit structures fabricated with direct metal laser sintering and vacuum casting techniques.

Authors:  Raquel Castillo Oyagüe; Andrés Sánchez-Turrión; José Francisco López-Lozano; Javier Montero; Alberto Albaladejo; María Jesús Suárez-García
Journal:  Odontology       Date:  2011-11-11       Impact factor: 2.634

2.  Evaluation of a conventional glass ionomer cement with new zinc formulation: effect of coating, aging and storage agents.

Authors:  Julius Zoergiebel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2012-05-02       Impact factor: 3.573

3.  The effect of glass synthesis route on mechanical and physical properties of resultant glass ionomer cements.

Authors:  A Wren; O M Clarkin; F R Laffir; C Ohtsuki; I Y Kim; M R Towler
Journal:  J Mater Sci Mater Med       Date:  2009-05-21       Impact factor: 3.896

4.  Effect of heat application on the mechanical behaviour of glass ionomer cements.

Authors:  Ulrike Menne-Happ; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2013-06-06       Impact factor: 3.573

5.  Bioactive sol-gel glass added ionomer cement for the regeneration of tooth structure.

Authors:  Jung-Young Choi; Hae-Hyoung Lee; Hae-Won Kim
Journal:  J Mater Sci Mater Med       Date:  2008-05-16       Impact factor: 3.896

6.  Dental materials for primary dentition: are they suitable for occlusal restorations? A two-body wear study.

Authors:  D Lazaridou; R Belli; N Krämer; A Petschelt; U Lohbauer
Journal:  Eur Arch Paediatr Dent       Date:  2014-10-25

7.  Shear Bond Strength Evaluation of Resin Composite Bonded to GIC Using Different Adhesives.

Authors:  Ruchi Gupta; Sonam Mahajan
Journal:  J Clin Diagn Res       Date:  2015-01-01

8.  Effect of antibacterial agents on the surface hardness of a conventional glass-ionomer cement.

Authors:  Tamer Tüzüner; Tezer Ulusu
Journal:  J Appl Oral Sci       Date:  2012-02       Impact factor: 2.698

9.  Polymeric-calcium phosphate cement composites-material properties: in vitro and in vivo investigations.

Authors:  Rania M Khashaba; Mervet M Moussa; Donald J Mettenburg; Frederick A Rueggeberg; Norman B Chutkan; James L Borke
Journal:  Int J Biomater       Date:  2010-07-29

10.  Improvement of enamel bond strengths for conventional and resin-modified glass ionomers: acid-etching vs. conditioning.

Authors:  Ling Zhang; Tian Tang; Zhen-liang Zhang; Bing Liang; Xiao-miao Wang; Bai-ping Fu
Journal:  J Zhejiang Univ Sci B       Date:  2013-11       Impact factor: 3.066

View more