Literature DB >> 11202248

Safe and effective placement of two bipolar silicone leads in the cephalic vein using a hydrophilic guidewire and a split introducer.

A Da Costa1, E Faure, C Romeyer, B Samuel, M Messier, M Lamaud, K Isaaz.   

Abstract

The cephalic vein (CV) is preferable to the subclavian vein for implanting permanent pacing leads because of fewer complications. Unfortunately, this access is unusable in a substantial number of patients. This prospective study evaluates a technique to increase CV access for the placement of two silicone bipolar leads used in DDD pulse generator implants. A standard cephalic cutdown was performed under local anesthesia and a hydrophilic guidewire (HGW) threaded in the CV. The first (ventricular) bipolar lead was then introduced and positioned. When possible, introduction of the second (atrial) lead followed the same direct access. A failed introduction led to a modified procedure (MP) relying on a "split" introducer (8-9 Fr Plastimed) advanced with a circular motion over the HGW, then removal of the dilator, removal of the HGW, insertion of the pacing lead into the sheath with placement in the right atrium, followed by sheath withdrawal. Over an 18-month period, 90 consecutive patients had DDD pacemakers implanted. The CV was accessible in 76 (84.5%) of 90 patients and the direct introduction of the ventricular lead was obtained in 74 (97.4%) of these. Atrialization proceeded as follows: direct access CV in 14 (18%) of 76 patients, MP access in 54 (71%) of 76 patients, and MP failure in 8 (11%) of 76 patients. Overall, this approach allowed cephalic dual insertion in 68 (89%) of 76 patients. In conclusion, the modified procedure presented in this study allows a dual catheterization with bipolar leads in 89% of patients when a CV is available. This significantly improves the success rate for dual bipolar lead implants in this configuration.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11202248     DOI: 10.1111/j.1540-8159.2000.tb00777.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Feasibility and accuracy of pre-procedure imaging of the proximal cephalic vein by duplex ultrasonography in pacemaker and defibrillator implantation.

Authors:  Jan-Yow Chen; Kuan-Cheng Chang; Yu-Chin Lin; Hsiang-Tai Chou; Jui-Sung Hung
Journal:  J Interv Card Electrophysiol       Date:  2004-02       Impact factor: 1.900

2.  Clinical predictors of successful cephalic vein access for implantation of endocardial leads.

Authors:  Bradley P Knight; Kristen Curlett; Hakan Oral; Frank Pelosi; Fred Morady; S Adam Strickberger
Journal:  J Interv Card Electrophysiol       Date:  2002-10       Impact factor: 1.900

  2 in total