Characteristics and results of epicardial pacing in neonates and infants.

E Villain1, H Martelli, D Bonnet, L Iserin, G Butera, J Kachaner.   

Abstract

The results of epicardial pacing in infants with isolated congenital complete atrioventricular block (CAVB) are reported. Thirty-four patients, aged 1 day to 20 months (22 patients < 1 month), were paced between 1988 and 1998. Thirty had bradycardia < 50 beats/min with symptoms in 12 patients, and 4 patients were paced because of associated ventricular ectopy or prolonged QT interval. In thirty cases, the electrodes were implanted through a left thoracotomy and connected to an abdominal generator; in four, the subxyphoid approach was preferred. Twenty-two children had dual chamber units. There was no operative death, but three patients died later of cardiomyopathy. Seven infants were reoperated for electrode displacement, infection, exit block, and pacemaker sensitivity. Chronic ventricular thresholds ranged from 0.3 to 2 V except in one case (4 V) and proper atrial sensing was lost in two cases. All children are doing well and the generator has lasted at least 5 years in 16 cases. In conclusion, epicardial pacing in infants with CAVB can be done with satisfactory results. There was no mortality in relation with pacing and thresholds have improved with the use of steroid-eluting electrodes. The deep location of the generator prevents cutaneous erosion and allows implantation of large units with a longer life duration.

Entities:  

Mesh:

Year:  2000        PMID: 11202246     DOI: 10.1111/j.1540-8159.2000.tb00775.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

1.  An alternate technique to pacing in complex congenital heart disease: assessment of the left thoracotomy approach.

Authors:  Ashley D Roberts; Suvro Sett; Jacques Leblanc; Shubhayan Sanatani
Journal:  Can J Cardiol       Date:  2006-05-01       Impact factor: 5.223

2.  Electro-stimulation in preterm neonates with congenital auriculo-ventricular block. Report of three cases.

Authors:  Thameur Rakza; Nahida Rifai; Armelle Delapintiere; Eric Magnenant; Guy Vaksmann; Michel Bonnevalle; Pierre Lequien; Laurent Storme
Journal:  Eur J Pediatr       Date:  2003-12-19       Impact factor: 3.183

3.  Endocardial pacemaker implantation in neonates and infants.

Authors:  Canan Ayabakan; Eric Rosenthal
Journal:  Indian Pacing Electrophysiol J       Date:  2006-04-01

4.  Do all children with congenital complete atrioventricular block require permanent pacing?

Authors:  Christian Balmer; Urs Bauersfeld
Journal:  Indian Pacing Electrophysiol J       Date:  2003-07-01

5.  Thoracic epidural infusion with chloroprocaine for postoperative analgesia following epicardial pacemaker placement in an infant.

Authors:  Mineto Kamata; Marco Corridore; Joseph D Tobias
Journal:  J Pain Res       Date:  2014-10-23       Impact factor: 3.133

6.  Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

Authors:  Roberto Costa; Katia Regina da Silva; Martino Martinelli Filho; Roger Carrillo
Journal:  Arq Bras Cardiol       Date:  2017-09-04       Impact factor: 2.000

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.