Literature DB >> 11202151

Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles.

J B Matthews1, T R Green, M H Stone, B M Wroblewski, J Fisher, E Ingham.   

Abstract

The response of primary murine macrophages and the U937 human histiocytic cell line to challenge with clinically relevant UHMWPE wear debris of known particle size and dose was evaluated. Particles with mean sizes of 0.24, 0.45, 1.71, 7.62 and 88 microm were co-cultured with cells for 24 hours prior to assessment of cell viability and production of the osteolytic mediators IL-1beta, IL-6, TNFalpha and, in supernatants from murine phagocytes, PGE2 and GM-CSF. All particle fractions were evaluated at particle volume (microm3) to cell number ratios of 10 : 1 and 100 : 1 (and, additionally, 0.1 : 1 and 1 : 1 for U937 cells). These ratios had previously been identified as the most stimulatory and clinically relevant. Although the results for the cell line were highly variable, stimulation with phagocytosable particles (range 0.1 to 15 microm) resulted in enhanced levels of cytokine secretion by both murine macrophages and U937 histiocytes. The most biologically active particles were sub-micrometre in size. However, U937 cells responded to wear debris at much lower particle volume to cell number ratios (>0.1 microm3 per cell) than the murine cells (> 10 microm3 per cell). No GM-CSF was produced by particle or LPS stimulated murine macrophages. Similarly, U937 histiocytes failed to secrete any IL-1beta. Neither macrophage population responded to stimulation with the largest (88 microm) particles. These results confirm earlier findings and suggest that the size of UHMWPE wear particles is a critical factor in macrophage activation. Moreover, primary murine macrophages have been demonstrated to be a suitable model for studying cell-particle interactions in vitro.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11202151

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  14 in total

1.  Quantifying subtle but persistent peri-spine inflammation in vivo to submicron cobalt-chromium alloy particles.

Authors:  Nadim James Hallab; Frank W Chan; Megan L Harper
Journal:  Eur Spine J       Date:  2012-03-10       Impact factor: 3.134

2.  Assessment of epidural versus intradiscal biocompatibility of PEEK implant debris: an in vivo rabbit model.

Authors:  Nadim J Hallab; Qi-Bin Bao; Tim Brown
Journal:  Eur Spine J       Date:  2013-08-31       Impact factor: 3.134

3.  Biological activity and migration of wear particles in the knee joint: an in vivo comparison of six different polyethylene materials.

Authors:  S Utzschneider; V Lorber; M Dedic; A C Paulus; C Schröder; O Gottschalk; M Schmitt-Sody; V Jansson
Journal:  J Mater Sci Mater Med       Date:  2014-02-22       Impact factor: 3.896

4.  Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms.

Authors:  Marco S Caicedo; Lauryn Samelko; Kyron McAllister; Joshua J Jacobs; Nadim J Hallab
Journal:  J Orthop Res       Date:  2013-06-21       Impact factor: 3.494

5.  Implant debris particle size affects serum protein adsorption which may contribute to particle size-based bioreactivity differences.

Authors:  Anand Reddy; Marco S Caicedo; Lauryn Samelko; Joshua J Jacobs; Nadim James Hallab
Journal:  J Long Term Eff Med Implants       Date:  2014

6.  Polyethylene wear particles induce TLR 2 upregulation in the synovial layer of mice.

Authors:  A C Paulus; J Frenzel; A Ficklscherer; B P Roßbach; C Melcher; V Jansson; S Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-11-19       Impact factor: 3.896

7.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

8.  The biological response to nanometre-sized polymer particles.

Authors:  Aiqin Liu; Laura Richards; Catherine L Bladen; Eileen Ingham; John Fisher; Joanne L Tipper
Journal:  Acta Biomater       Date:  2015-05-22       Impact factor: 8.947

9.  Analysis of wear, wear particles, and reduced inflammatory potential of vitamin E ultrahigh-molecular-weight polyethylene for use in total joint replacement.

Authors:  C L Bladen; S Teramura; S L Russell; K Fujiwara; J Fisher; E Ingham; N Tomita; J L Tipper
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

10.  In vitro analysis of the cytotoxic and anti-inflammatory effects of antioxidant compounds used as additives in ultra high-molecular weight polyethylene in total joint replacement components.

Authors:  C L Bladen; L Tzu-Yin; J Fisher; J L Tipper
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-08-22       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.