Literature DB >> 11201772

Laser in situ keratomileusis to correct residual myopia after cataract surgery.

M J Ayala1, J J Pérez-Santonja, A Artola, P Claramonte, J L Alió.   

Abstract

PURPOSE: To evaluate the effectiveness, predictability, and safety of laser in situ keratomileusis (LASIK) for correcting residual myopia after cataract surgery with intraocular lens implantation.
METHODS: Twenty-two eyes of 22 patients underwent LASIK for the correction of residual myopia after cataract surgery. LASIK was carried out using the Chiron Automated Corneal Shaper and the NIDEK EC-5000 excimer laser. In all eyes, the follow-up was 12 months.
RESULTS: Before LASIK, 1 eye (4.5%) had an uncorrected visual acuity of 0.5 or better; 12 months after LASIK, 10 eyes (45.4%) achieved this level of visual acuity and 0 eyes achieved 1.00 or better. Before LASIK, mean refraction was -2.90 +/- 1.80 D; 12 months after LASIK it decreased significantly to 0.40 +/- 0.60 D (P < .01). In 18 eyes (81.8%) at 12 months after LASIK, spherical equivalent refraction was within +/-1.00 D of emmetropia; 11 eyes (50%) were within 0.50 D. No vision-threatening complications occurred.
CONCLUSION: LASIK with the Automated Corneal Shaper and Nidek EC-5000 excimer laser was an effective, predictable, stable, and safe procedure for correcting residual myopia after cataract surgery. No intraocular lens or cataract incision related complications occurred when LASIK was performed at least 3 months after phacoemulsification.

Entities:  

Mesh:

Year:  2001        PMID: 11201772     DOI: 10.3928/1081-597X-20010101-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  LASIK after retinal detachment surgery.

Authors:  R Sinha; T Dada; L Verma; D B Chaudhury; R Tandon; R B Vajpayee
Journal:  Br J Ophthalmol       Date:  2003-05       Impact factor: 4.638

2.  Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

Authors:  Majid Moshirfar; Michael V McCaughey; Luis Santiago-Caban
Journal:  Expert Rev Ophthalmol       Date:  2014-12

3.  Central corneal thickness in a Jordanian population and its association with different types of Glaucoma: cross-sectional study.

Authors:  Sana' Muhsen; Feras Alkhalaileh; Mohammad Hamdan; Saif Aldeen AlRyalat
Journal:  BMC Ophthalmol       Date:  2018-10-29       Impact factor: 2.209

4.  Predicting the necessity of LASIK enhancement after cataract surgery in patients with multifocal IOL implantation.

Authors:  Pinakin Gunvant; Anna Ablamowicz; Subba Gollamudi
Journal:  Clin Ophthalmol       Date:  2011-09-08

5.  Off-Label Use of Phakic Intraocular Lens with a "Piggyback" Technique.

Authors:  Tadgh Schempf; Hoon C Jung
Journal:  Case Rep Ophthalmol       Date:  2018-11-21

6.  Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error.

Authors:  Alahmady Hamad Alsmman Hassan; Khulood M Sayed; Mohammed ElAgooz; Ashraf Mostafa Elhawary
Journal:  J Ophthalmol       Date:  2016-05-30       Impact factor: 1.909

7.  Photorefractive keratectomy for correcting residual refractive error following cataract surgery with premium intraocular lens implantation.

Authors:  Yuan-Yao Fan; Chi-Chin Sun; Hung-Chi Chen; David Hui-Kang Ma
Journal:  Taiwan J Ophthalmol       Date:  2018 Jul-Sep
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.