Literature DB >> 11201287

Evaluation of individually ventilated cage systems for laboratory rodents: occupational health aspects.

A Renström1, G Björing, A U Höglund.   

Abstract

New ventilated caging systems for laboratory animals were compared with conventional caging regarding allergen distribution, ergonomic suitability, cage environment and animal welfare. This paper presents occupational health evaluations. Mice were placed in individually ventilated cage (IVC) systems, a ventilated cabinet, and in cages on open shelves (conventional husbandry). The IVC systems were studied at negative and positive airflow. Aeroallergens were sampled on filters (n = 204, including controls) in undisturbed rooms and during cage changing. Concentrations of mouse urinary allergen (Mus m 1) in filter eluates were measured using sandwich ELISA. An ergonomic evaluation was performed with measurement of traction forces. Staff exposure during cage changing was high in all systems, range 116-4430 ng Mus m 1/m3. In undisturbed animal rooms, allergen levels were orders of magnitude higher when using conventional caging compared with ventilated systems; P < 0.001. At positive pressure both IVCs leaked allergen (median Mus m 1 concentration was < 0.08 ng/m3 at negative, but 6.5 ng/m3 (IVC1) and 0.8 ng/m3 (IVC2S) at positive pressure). The IVC systems had ergonomic disadvantages compared with the conventional husbandry and the ventilated cabinet, for instance with cages in unsuitable working heights. Ventilated husbandry solutions reduce levels of airborne allergen substantially at negative pressure, but are ergonomically less suitable. To prevent allergen exposure during cage changing, we propose that this procedure should be performed under ventilated conditions. Producers and users must cooperate in optimizing animal caging systems for both animals and staff.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11201287     DOI: 10.1258/0023677011911363

Source DB:  PubMed          Journal:  Lab Anim        ISSN: 0023-6772            Impact factor:   2.471


  15 in total

Review 1.  A risk-based approach to reducing exposure of staff to laboratory animal allergens.

Authors:  Lynda Westall; Ian R Graham; James Bussell
Journal:  Lab Anim (NY)       Date:  2015-01       Impact factor: 12.625

2.  Implications of natural occlusion of ventilated racks on ammonia and sanitation practices.

Authors:  Michelle A Creamer; Joann Petty; Tara Martin; Valerie Bergdall; Judy M Hickman-Davis
Journal:  J Am Assoc Lab Anim Sci       Date:  2014-03       Impact factor: 1.232

3.  Antimicrobial Stewardship in Laboratory Animal Facilities.

Authors:  Heather L Narver
Journal:  J Am Assoc Lab Anim Sci       Date:  2017-01-01       Impact factor: 1.232

4.  Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

Authors:  Roger S Geertsema; Claire E Lindsell
Journal:  J Am Assoc Lab Anim Sci       Date:  2015-09       Impact factor: 1.232

5.  PCR Prevalence of Murine Opportunistic Microbes and their Mitigation by Using Vaporized Hydrogen Peroxide.

Authors:  Natalie H Ragland; Emily L Miedel; Robert W Engelman
Journal:  J Am Assoc Lab Anim Sci       Date:  2019-02-22       Impact factor: 1.232

Review 6.  Laboratory Animal Allergy in the Modern Era.

Authors:  Meinir Jones
Journal:  Curr Allergy Asthma Rep       Date:  2015-12       Impact factor: 4.806

7.  Morphological, physiological and behavioural evaluation of a 'Mice in Space' housing system.

Authors:  Dieter Blottner; Najet Serradj; Michele Salanova; Chadi Touma; Rupert Palme; Mitchell Silva; Jean Marie Aerts; Daniel Berckmans; Laurence Vico; Yi Liu; Alessandra Giuliani; Franco Rustichelli; Ranieri Cancedda; Marc Jamon
Journal:  J Comp Physiol B       Date:  2009-01-08       Impact factor: 2.200

8.  Influence of 5 different caging types and the use of cage-changing stations on mouse allergen exposure.

Authors:  Susan Feistenauer; Ingrid Sander; Jörg Schmidt; Eva Zahradnik; Monika Raulf; Markus Brielmeier
Journal:  J Am Assoc Lab Anim Sci       Date:  2014-07       Impact factor: 1.232

9.  Impact of IVC housing on emotionality and fear learning in male C3HeB/FeJ and C57BL/6J mice.

Authors:  Magdalena Kallnik; Ralf Elvert; Nicole Ehrhardt; Daniela Kissling; Esther Mahabir; Gerd Welzl; Theresa Faus-Kessler; Martin Hrabé de Angelis; Wolfgang Wurst; Jörg Schmidt; Sabine M Hölter
Journal:  Mamm Genome       Date:  2007-04-13       Impact factor: 3.224

Review 10.  Rodent allergens.

Authors:  Wanda Phipatanakul
Journal:  Curr Allergy Asthma Rep       Date:  2002-09       Impact factor: 4.919

View more