Literature DB >> 11200042

Experience in snuffbox arteriovenous fistulae for hemodialysis.

J K Lee1, T T Sara.   

Abstract

Sixty-five patients with "Snuffbox" arteriovenous fistulae for hemodialysis were reviewed. The procedure was performed under local anaesthesia as an outpatient procedure. It was done as a "standby" procedure for 41.5% of patients with Chronic Ambulatory Peritoneal Dialysis. 58.5% of patients had the procedure done for primary hemodialysis. Patency was assessed as presence of an engorged vein and presence of thrill. This was assessed routinely at 4 to 6 weeks after the procedure. Patency rate was noted to be 83%. The commonest complication was thrombosis of the arteriovenous anastomosis. Some patients required repeated procedure at a more proximal site. Further study to determine the blood flow rate provided by the anastomosis, and comparison with other anatomical sites is necessary.

Entities:  

Mesh:

Year:  2000        PMID: 11200042

Source DB:  PubMed          Journal:  Med J Malaysia        ISSN: 0300-5283


  1 in total

1.  Distal-to-Snuffbox Arteriovenous Fistula.

Authors:  Dale Maharaj; Michael James Ramdass; Rayaad Baksh; Adedapo Oladiran; Emerson Budhoo
Journal:  Int J Angiol       Date:  2018-06-16
  1 in total