Literature DB >> 11199992

A compactly integrated flow cell with a chemiluminescent FIA system for determining lactate concentration in serum.

H Nakamura1, Y Murakami, K Yokoyama, E Tamiya, I Karube, M Suda, S Uchiyama.   

Abstract

We have fabricated an integrated flow cell as a total microanalysis system (microTAS). This flow cell (size, 15 x 20 mm; total inner volume, 12.2 microL) was designed for a rational analyzing system of lactate determination for serum. This cell was made by micromachining techniques and consisted of two hollows of a lactate oxidase (LOD) reactor and a mixing cell, a spiral groove, and three penetrated holes. To form the reactor and capillary, these patterns, etched on a silicon wafer, were attached to a glass plate by the anodic bonding method. A photodiode was put under part of the spiral capillary. The compactly accumulated devices were integrated into a flow injection analysis (FIA) system. In the flow cell, lactate was catalyzed to pyruvate and hydrogen peroxide at the LOD reactor; subsequently, hydrogen peroxide reacted with the luminol-ferricyanic reagent at the mixing cell. The resulting chemiluminescent light was detected by the photodiode. Using the miniaturized flow cell, the sample volume for one measurement was greatly reduced to 0.2 microL. The response to lactate was obtained within 30 s and was linear between 0.5 and 5.0 mM (4.5 and 45 mg/dL) lactate with excellent correlative variances of 3.2% (average of three measurements at 5.0 mM). For practical application, the lactate concentration in control human serum was determined using this system. The results showed a good correlation coefficient (r = 0.979) with the results obtained by the spectrophotometric reference method. No difference in sera (normal or pathological) was found. Consequently, this integrated flow cell shows potential as a clinical device for lactate determination in serum. In this article, the effect of the design on the chemiluminescent FIA system is also described.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11199992     DOI: 10.1021/ac000855u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  A portable luminometer with a disposable electrochemiluminescent biosensor for lactate determination.

Authors:  Antonio Martínez-Olmos; Julio Ballesta-Claver; Alberto J Palma; Maria Del Carmen Valencia-Mirón; Luis Fermin Capitán-Vallvey
Journal:  Sensors (Basel)       Date:  2009-09-28       Impact factor: 3.576

2.  Microfluidic systems for pathogen sensing: a review.

Authors:  Jürgen Mairhofer; Kriemhilt Roppert; Peter Ertl
Journal:  Sensors (Basel)       Date:  2009-06-17       Impact factor: 3.576

Review 3.  Smartphone-based mobile biosensors for the point-of-care testing of human metabolites.

Authors:  Meiying Zhang; Xin Cui; Nan Li
Journal:  Mater Today Bio       Date:  2022-04-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.