Literature DB >> 11199968

Signal amplification using "spot-on-a-chip" technology for the identification of proteins via MALDI-TOF MS.

S Ekström1, D Ericsson, P Onnerfjord, M Bengtsson, J Nilsson, G Marko-Varga, T Laurell.   

Abstract

The presented "spot-on-a-chip" technology enables easy enrichment of samples in the low nanomolar (1-5 nM) range and provides a fast and reliable automated sample preparation method for performing matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis with high sensitivity and throughput. Through microdispensing, which allows accurate deposition of 60-pL droplets, dilute samples were enriched by making multiple droplet depositions in nanovials. The sample was confined to a defined spot area (300 x 300 microm), and multiple depositions increase the surface density of analyte in the nanovial, thereby providing detection of low attomole levels. The impact of the nanovial geometry with respect to the MALDI-TOF MS resolution for peptides deposited in the microfabricated silicon vials was investigated and the optimal geometry and size were determined. The spot-on-a-chip technology, that is, the combination of microdispensing, micromachined silicon nanovials and on-spot enrichment provides a signal amplification of at least 10-50 times as compared to an ordinary sample preparation. The linearity of the enrichment effect is shown by the analysis of a peptide mixture at the 5 nM level. The signal amplification provided by the spot-on-a-chip enrichment is demonstrated by the analysis of relevant biological samples, interleukin-8 from a spiked cell supernatant, and by successful protein identification of an excised spot from a high-sensitivity silver-stained two-dimensional electrophoresis gel separation.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11199968     DOI: 10.1021/ac000734u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

Review 1.  mRna expression analysis of tissue sections and single cells.

Authors:  J Eberwine; J E Kacharmina; C Andrews; K Miyashiro; T McIntosh; K Becker; T Barrett; D Hinkle; G Dent; P Marciano
Journal:  J Neurosci       Date:  2001-11-01       Impact factor: 6.167

2.  On-line single droplet deposition for MALDI mass spectrometry.

Authors:  Xia Zhang; Damien A Narcisse; Kermit K Murray
Journal:  J Am Soc Mass Spectrom       Date:  2004-10       Impact factor: 3.109

3.  Optimized sample preparation for MALDI mass spectrometry analysis of protected synthetic peptides.

Authors:  Audrey M Schaiberger; Jason A Moss
Journal:  J Am Soc Mass Spectrom       Date:  2008-01-31       Impact factor: 3.109

4.  Improving the signal intensity and sensitivity of MALDI mass spectrometry by using nanoliter spots deposited by induction-based fluidics.

Authors:  Tingting Tu; Andrew D Sauter; Andrew D Sauter; Michael L Gross
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-08       Impact factor: 3.109

5.  Identification of cyst wall proteins of the hypotrich ciliate Euplotes encysticus using a proteomics approach.

Authors:  Bangzheng Wang; Tao Niu; Muhammad Zeeshan Bhatti; Fenfen Chen; Lin Wu; Jiwu Chen
Journal:  J Microbiol       Date:  2017-06-30       Impact factor: 3.422

6.  Miniaturizing sample spots for matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Tingting Tu; Michael L Gross
Journal:  Trends Analyt Chem       Date:  2009-08-01       Impact factor: 12.296

7.  Droplet Microfluidics with MALDI-MS Detection: The Effects of Oil Phases in GABA Analysis.

Authors:  Sara E Bell; Insu Park; Stanislav S Rubakhin; Rashid Bashir; Yurii Vlasov; Jonathan V Sweedler
Journal:  ACS Meas Sci Au       Date:  2021-08-24
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.