Literature DB >> 11199644

Microleakage study of flowable composite resin systems.

A M Estafan1, D Estafan.   

Abstract

The purpose of this in vitro microleakage study was to evaluate four low-viscosity composite resin systems. Each resin system included the corresponding bonding agent for each respective flowable composite. A hybrid material was used as a control. A total of 75 noncarious, freshly extracted human teeth were prepared with a Class 5 occlusal preparation and a gingival preparation at the cementoenamel junction. The materials were inserted according to the manufacturers' recommendations using the single-component bonding agent for each system. Teeth were thermocycled 800 times between 5 degrees C and 55 degrees C with 30-second dwell times. The teeth were then coated with nail polish 1 mm short of the restoration, placed in a basic fuchsin dye for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a scale of 0 (no leakage) to 3 (axial wall). Results were evaluated with the Fisher's exact test. The results of the study indicate that there was no leakage at the enamel margin of any restorations. No statistically significant differences in microleakage were found in dentin/cementum margins among the samples in the experimental group or between the experimental group and control group. The results indicate flowable composites demonstrate resistance to microleakage in both enamel and cementum/dentin margins similar to TPH hybrid composite.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11199644

Source DB:  PubMed          Journal:  Compend Contin Educ Dent        ISSN: 1548-8578


  4 in total

1.  Radiopacity of dental restorative materials.

Authors:  Tomaž Hitij; Aleš Fidler
Journal:  Clin Oral Investig       Date:  2012-07-24       Impact factor: 3.573

2.  Evaluating the Marginal Integrity of Bulk Fill Fibre Reinforced Composites in Bio-mimetically Restored Tooth.

Authors:  Arun Kumar Patnana; V Narsimha Rao Vanga; Srinivas Kumar Chandrabhatla
Journal:  J Clin Diagn Res       Date:  2017-06-01

3.  An in vitro microleakage study of class V cavities restored with a new self-adhesive flowable composite resin versus different flowable materials.

Authors:  Mostafa Sadeghi
Journal:  Dent Res J (Isfahan)       Date:  2012-07

4.  The evaluation of various restoration techniques on internal adaptation of composites in class v cavities.

Authors:  D Dionysopoulos; C Papadopoulos; E Koliniotou-Koumpia
Journal:  Int J Biomater       Date:  2014-10-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.