Literature DB >> 11197819

Prevention of paraplegia in transluminally placed endoluminal prosthetic grafts for descending thoracic aortic aneurysms.

H Midorikawa1, S Hoshino, F Iwaya, T Igari, K Satou, K Ishikawa.   

Abstract

OBJECTIVE: To evaluate the efficacy of a temporary balloon occlusion test for the prevention of paraplegia following transluminally placed endoluminal prosthetic grafts for descending thoracic aortic aneurysms. SUBJECTS AND METHODS: Two occlusion balloons were inserted via the brachial and femoral arteries and positioned in the proximal and distal neck of the descending thoracic aortic aneurysms using fluoroscopy. After temporary occlusion of the thoracic aorta by inflation of both the proximal and distal balloons, the evoked spinal potential was measured for 15 mins. A maximum amplitude during temporary balloon occlusion test decreasing by more than 20% of the pre-balloon occlusion level was considered to be significant, enough to not perform transluminally placed endoluminal prosthetic grafts, but instead an open repair. The test was applied in 12 cases (9 males and 3 females, 50-86 years old). All aneurysms were located between the Th6 and Th12 with a maximum diameter of 40-70 mm, and average of 56 mm.
RESULTS: The changes in maximum amplitude of evoked spinal potential remained within 20% of the value before balloon occlusion in 11 cases. Transluminally placed endoluminal prosthetic grafts were performed in these 11 cases and no instance of paraplegia or other complication relating to the test was observed. Deployment of stent-grafts was successful in 10 cases (91%).
CONCLUSION: It is suggested that the preoperative measurement of evoked spinal potential during temporary balloon occlusion is clinically useful for the assessment of the risk to paraplegia occurring in transluminally placed endoluminal prosthetic grafts.

Entities:  

Mesh:

Year:  2000        PMID: 11197819     DOI: 10.1007/bf03218249

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  26 in total

Review 1.  New and future approaches for spinal cord protection.

Authors:  L G Svensson
Journal:  Semin Thorac Cardiovasc Surg       Date:  1997-07

2.  Delayed onset of ascending paralysis after thoracic aortic stent graft deployment.

Authors:  K Kasirajan; B Dolmatch; K Ouriel; D Clair
Journal:  J Vasc Surg       Date:  2000-01       Impact factor: 4.268

3.  Preoperative spinal cord arteriography in aneurysmal disease of the descending thoracic and thoracoabdominal aorta: preliminary results in 45 patients.

Authors:  E Kieffer; T Richard; J Chiras; G Godet; E Cormier
Journal:  Ann Vasc Surg       Date:  1989-01       Impact factor: 1.466

Review 4.  Abdominal aortic aneurysm.

Authors:  C B Ernst
Journal:  N Engl J Med       Date:  1993-04-22       Impact factor: 91.245

5.  Adequacy of ascending aorta-descending aorta shunt during cross-clamping of the thoracic aorta for prevention of spinal cord injury.

Authors:  J E Molina; J Cogordan; S Einzig; R W Bianco; T Rasmussen; R M Clack; B Borgwardt
Journal:  J Thorac Cardiovasc Surg       Date:  1985-07       Impact factor: 5.209

6.  Three-year experience with modular stent-graft devices for endovascular AAA treatment.

Authors:  W Stelter; T Umscheid; P Ziegler
Journal:  J Endovasc Surg       Date:  1997-11

7.  Adenosine-induced transient cardiac asystole enhances precise deployment of stent-grafts in the thoracic or abdominal aorta.

Authors:  G Dorros; J M Cohn
Journal:  J Endovasc Surg       Date:  1996-08

8.  The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta.

Authors:  M D Dake; D C Miller; R S Mitchell; C P Semba; K A Moore; T Sakai
Journal:  J Thorac Cardiovasc Surg       Date:  1998-11       Impact factor: 5.209

9.  Experience with the Stentor endograft at four Italian centers.

Authors:  G Coppi; R Pacchioni; R Moratto; S Gennai; G A Farello; G Bergamaschi; C Rabbia; D Rossato; F Ponzio; V Stancanelli; E Piccinini
Journal:  J Endovasc Surg       Date:  1998-08

10.  The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms.

Authors:  K Grabitz; W Sandmann; K Stühmeier; B Mainzer; E Godehardt; B Ohle; U Hartwich
Journal:  J Vasc Surg       Date:  1996-02       Impact factor: 4.268

View more
  1 in total

1.  Long-term results of endoluminal grafting for descending thoracic aortic aneurysms.

Authors:  Hirofumi Midorikawa; Tomohiro Ogawa; Kouichi Satou; Shunichi Hoshino; Shinya Takase; Hitoshi Yokoyama
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.