Literature DB >> 11195511

Sampling and analysis of airborne particulate matter and aerosols using in-needle trap and SPME fiber devices.

J A Koziel1, M Odziemkowski, J Pawliszyn.   

Abstract

A needle trap device (NTD) and commercial poly(dimethylsiloxane) (PDMS) 7-microm film thickness solid-phase microextraction (SPME) fibers were used for the sampling and analysis of aerosols and airborne particulate matter (PM) from an inhaler-administered drug, spray insect repellant, and tailpipe diesel exhaust. The NTD consisted of a 0.53-mm o.d. stainless steel needle having 5 mm of quartz wool packing section near the needle tip. Samples were collected by drawing air across the NTD with a Luertip syringe or via direct exposure of the SPME fiber. The mass loading of PM was varied by adjusting the volume of air pulled through the NTD or by varying the sampling time for the SPME fiber. The air volumes ranged from 0.1 to 50 mL, and sampling times varied from 10 s to 16 min. Particulates were either trapped on the needle packing or sorbed onto the SPME fiber. The devices were introduced to a chromatograph/mass spectrometer (GC/MS) injector for 5 min desorption. In the case of the NTD, 10 microL of clean air was delivered by a gas-tight syringe to aid the introduction of desorbed analytes. The compounds sorbed onto particles extracted by the SPME fiber or trapped in the needle device were desorbed in the injector and no carry-over was observed. Both devices performed well in extracting airborne polycyclic aromatic hydrocarbons (PAHs) in diesel exhaust, triamcinolone acetonide in a dose of asthma drug and DEET in a dose of insect repellant spray. Results suggest that the NTDs and PDMS 7-microm fibers can be used for airborne particulate sampling and analysis, providing a simple, fast, reusable, and cost-effective screening tool. The advantage of the SPME fiber is the open-bed geometry allowing spectroscopic investigations of particulates; for example, with Raman microspectroscopy.

Entities:  

Year:  2001        PMID: 11195511     DOI: 10.1021/ac000835s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Application of a needle trap device packed with a MIP@MOF nano-composite for efficient sampling and determination of airborne diazinon pesticide.

Authors:  Razzagh Rahimpoor; Ali Firoozichahak; Saber Alizadeh; Danial Soleymani-Ghoozhdi; Faeze Mehregan
Journal:  RSC Adv       Date:  2022-05-31       Impact factor: 4.036

2.  Nano-hydroxyapatite/polyaniline composite as an efficient sorbent for sensitive determination of the polycyclic aromatic hydrocarbons in air by a needle trap device.

Authors:  Ali Akbar Alinaghi Langari; Saber Alizadeh; Shiva Soury; Ali Firoozichahak; Davood Nematollahi; Parsa Mohammad Alizadeh; Nasim Sanaei
Journal:  RSC Adv       Date:  2020-11-19       Impact factor: 4.036

3.  Efficient extraction of aromatic amines in the air by the needle trap device packed with the zirconium based metal-organic framework sorbent.

Authors:  Ali Akbar Alinaghi Langari; Ali Firoozichahak; Saber Alizadeh; Davood Nematollahi; Maryam Farhadian
Journal:  RSC Adv       Date:  2020-04-03       Impact factor: 4.036

4.  Determination of halogenated hydrocarbons in urine samples using a needle trap device packed with Ni/Zn-BTC bi-MMOF via the dynamic headspace method.

Authors:  Razzagh Rahimpoor; Ali Firoozichahak; Davood Nematollahi; Saber Alizadeh; Parsa Mohammad Alizadeh; Ali Akbar Alinaghi Langari
Journal:  RSC Adv       Date:  2021-06-17       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.