Literature DB >> 11194594

Efficacy and tolerability of continuous overdrive atrial pacing in atrial fibrillation.

C T Lam1, C P Lau, S K Leung, H F Tse, K L Lee, M O Tang, V Tsang.   

Abstract

Overdrive right atrial pacing has been used to prevent atrial fibrillation, but its efficacy in atrial fibrillation prevention and the patient tolerability and quality of life during high rate pacing remain uncertain. The objective of this study was to test the effects of a consistent atrial pacing algorithm that automatically paced the atrium at 30 ms shorter than the sinus P-P interval for atrial fibrillation prevention. Fifteen patients with sick sinus syndrome implanted with a Thera DR (model 7940 or 7960, Medtronic Inc.) were randomly programmed to rate adaptive dual chamber pacing (DDDR) or DDDR + consistent atrial pacing mode, each for an 8-week study period. The efficacy of consistent atrial pacing was assessed by the number of automatic mode switching and the number of premature atrial complexes. Symptoms and quality of life were assessed by the SF-36 quality of life questionnaire and an atrial fibrillation symptom checklist. The percentage of atrial pacing increased from 57 +/- 32% to 86 +/- 28%. Overall, there was no significant difference in the number of automatic mode switching episodes between DDDR and DDDR + consistent atrial pacing (47 +/- 90 vs 42 +/- 87, P > 0.05), but a significant reduction in premature atrial complexes by 74.7% (P < 0.001). There was no undue increase in atrial rate by the DDDR + consistent atrial pacing mode versus DDDR (63 +/- 13 vs 70 +/- 7 bpm). There was no significant difference in quality of life scores and symptom severity on frequency between the two modes of pacing, but a trend towards a lower frequency of symptoms in the DDDR + consistent atrial pacing mode compared with baseline (29.5 +/- 10.2 vs 25.1 +/- 9.7, P = 0.07). An algorithm that provides consistent atrial overdrive pacing can suppress atrial fibrillation triggering premature atrial complexes without the need to increase the overall atrial rate compared with conventional pacing. The algorithm appears to be well-tolerated, but further studies are needed to address the clinical impact of this atrial fibrillation prevention algorithm.

Entities:  

Mesh:

Year:  2000        PMID: 11194594     DOI: 10.1053/eupc.2000.0124

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

Review 1.  Pacing for atrial fibrillation.

Authors:  Chu-Pak Lau
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

Review 2.  Atrial pacing for the prevention of atrial fibrillation after coronary artery bypass graft surgery: a review of the literature.

Authors:  R A Archbold; R J Schilling
Journal:  Heart       Date:  2004-02       Impact factor: 5.994

3.  [Atrial pacing for prevention of atrial fibrillation. Influence of septal atrial pacing, atrial overdrive and AV-delay-optimization on atrial fibrillation burden].

Authors:  M Klein; N Klein; D Pfeiffer
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-09

Review 4.  The role of pacing in rhythm control and management of atrial fibrillation.

Authors:  John Silberbauer; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2007-05-02       Impact factor: 1.759

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.