Empirical dosimetric characterization of model I125-SL 125iodine brachytherapy source in phantom.

R E Wallace1.   

Abstract

Low-energy photon emitting radionuclides encapsulated for a permanent implant are routinely applied in prostate cancer brachytherapy. Before clinical use, a new source design requires full dosimetric analysis and calibration standardization. The results of one such experimental measurement and analysis are reported here for a new design of 125I source, model I125-SL. Dose measurements were made using standard methods employing thermoluminscent dosimeters in a water equivalent plastic phantom, in accord with the AAPM Task Group #43 recommendation of liquid water reference material. Precision machined bores in the phantom located dosimeters and source(s) in a reproducible fixed geometry providing for transverse-axis and angular dose profiles over a range of distances from 0.17 to 10 cm. The data were analyzed in terms of parameters recommended by AAPM TG43. The dose-rate constant, lambda, was evaluated by two methods, the first with reference to a 60Cobalt standard, accounting for response variation with photon energy spectrum. Second, the dose-rate constant was determined with reference to phantom measurements using NIST traceable calibrated model 6702 and 6711 sources. The radial dose function, g(r), the anisotropy function, F(r,theta), the anisotropy factor, phi(an)(r), and the point-source approximation anisotropy constant, phi(an), were derived from one- and two-dimensional dose distribution data measured in the phantom, accounting for finite dosimeter volume and with attention to interchip effects. The results are compared to TG43 and other existing data for 125I sources. The new source is comparable to the model 6711 source design.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11190963     DOI: 10.1118/1.1323980

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Clinical investigations on the spinal osteoblastic metastasis treated by combination of percutaneous vertebroplasty and (125)I seeds implantation versus radiotherapy.

Authors:  Zuozhang Yang; Jing Tan; Ruilian Zhao; Jiaping Wang; Hongpu Sun; Xiaoxue Wang; Lei Xu; Hua Jiang; Jinlei Zhang
Journal:  Cancer Biother Radiopharm       Date:  2012-09-25       Impact factor: 3.099

2.  Dosimetric parameters of three new solid core I-125 brachytherapy sources.

Authors:  Timothy D Solberg; John J DeMarco; Geoffrey Hugo; Robert E Wallace
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

3.  Evaluation of an automated seed loader for seed calibration in prostate brachytherapy.

Authors:  Shuying Wan; Chandra P Joshi; Greg Carnes; L John Schreiner
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.