Literature DB >> 11190951

An improved method for rapid objective measurement of gamma camera resolution.

T A Hander1, J L Lancaster, W McDavid, D T Kopp.   

Abstract

An improved method for an easy, rapid measurement of the intrinsic spatial resolution of a gamma camera is presented. A simplified model was previously developed based solely on mean and standard deviation measurements taken from a region of interest in bar pattern images. This led to an estimate of the modulation transfer function and the full width at half maximum (FWHM) of a line spread function (LSF). The improved method involved expanding the simplified model to incorporate input modulation, square wave input versus the assumed sinusoidal input, aperture (pixel) size, and scatter from the plastic in the bar pattern. The input square wave modulation was calculated to be unity for the typical bar patterns used for gamma camera quality control assessment. For the typical range of bar sizes available, in combination with the typical resolving capabilities of gamma cameras, the sinusoidal approximation of the bar pattern was found to be valid (<1% contribution to the measured resolution from higher harmonic frequencies present in a square wave input with an effective input modulation greater than unity by a factor of 4/pi). The aperture correction factor was calculated for numerous bar and pixel size combinations. Applying the aperture correction factor results in an improvement in the accuracy of the calculated FWHM values, especially for large apertures (pixel sizes). For a camera with a specified FWHM value of 3.5 mm, the simplified model predicts values ranging from 3.2 to 4.1 mm, when the acquisition matrix varies from 128(2) to 512(2). When the expanded model is used with the aperture correction applied, this range was reduced to 3.6-3.9 mm. The scatter correction further improved the calculated FWHM (from 3.6 to 3.8 mm). It is suggested that the expanded model should be used when more accurate measurements are desired, such as in acceptance testing.

Mesh:

Substances:

Year:  2000        PMID: 11190951     DOI: 10.1118/1.1328083

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Analytical and experimental FWHM of a gamma camera: theoretical and practical issues.

Authors:  Diego Cecchin; Davide Poggiali; Lucia Riccardi; Paolo Turco; Franco Bui; Stefano De Marchi
Journal:  PeerJ       Date:  2015-02-03       Impact factor: 2.984

2.  Observed inter-camera variability of clinically relevant performance characteristics for Siemens Symbia gamma cameras.

Authors:  S Cheenu Kappadath; William D Erwin; Richard E Wendt
Journal:  J Appl Clin Med Phys       Date:  2006-11-28       Impact factor: 2.102

3.  Automated phantom analysis for gamma cameras and SPECT: A methodology for use in a clinical setting.

Authors:  Tutku E Tazegul; Andrew M Polemi; Angela Snyder; Carl Snyder; Patricia G Collins
Journal:  J Appl Clin Med Phys       Date:  2020-11-03       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.