Literature DB >> 11190040

A comparison of visual acuity, predictability, and visual function outcomes after intracorneal ring segments and laser in situ keratomileusis.

B G Suiter1, M D Twa, J Ruckhofer, D J Schanzlin.   

Abstract

PURPOSE: To compare correction of low myopia by intrastromal corneal ring segments (ICRS) and by laser in situ keratomileusis (LASIK) with respect to early visual recovery and refractive outcomes.
METHODS: Eighty-two eyes implanted with ICRS in a phase III study for US Food and Drug Administration review were matched with 133 eyes treated with LASIK by criteria of age (> 18 years, < 65 years), preoperative myopia (-1.00 to -3.50 diopters [D]), astigmatism (< or = 1.00 D), single treatment, and attempted full correction. Examinations were performed preoperatively and postoperatively at days 1 and 7 and months 1 and 3. Visual acuity and manifest refraction data were collected retrospectively. Visual function scores were assigned, and summarized results were compared.
RESULTS: Uncorrected visual acuity was 20/20 or better at day 1 in 24% of eyes (20/82) after ICRS and in 55% of eyes (73/133) after LASIK, and at month 3 in 75% of eyes (58/77) after ICRS and in 67% of eyes (84/126) after LASIK. Spherical equivalent refraction at month 3 was within +/- 1.00 D of intended correction in 99% of eyes (76/77) after ICRS and in 96% of eyes (121/126) after LASIK. Excellent visual function scores were noted at month 3 in 90% of eyes (69/77) after ICRS and in 78% of eyes (98/126) after LASIK.
CONCLUSION: Patients treated with LASIK showed better uncorrected visual acuity immediately following surgery; however, beyond 1 month, patients treated with ICRS achieved better uncorrected visual acuity that continued to improve with time. Visual function scores indicate that ICRS eyes see at higher levels of uncorrected visual acuity than LASIK eyes do with the same refractive error. The ICRS and LASIK were comparable in the correction of mild myopia.

Entities:  

Mesh:

Year:  2000        PMID: 11190040      PMCID: PMC1298211     

Source DB:  PubMed          Journal:  Trans Am Ophthalmol Soc        ISSN: 0065-9533


  5 in total

1.  Studies of intrastromal corneal ring segments for the correction of low to moderate myopic refractive errors.

Authors:  D J Schanzlin
Journal:  Trans Am Ophthalmol Soc       Date:  1999

Review 2.  Laser in situ keratomileusis: literature review of a developing technique.

Authors:  S G Farah; D T Azar; C Gurdal; J Wong
Journal:  J Cataract Refract Surg       Date:  1998-07       Impact factor: 3.351

3.  The history and evolution of keratomileusis.

Authors:  J I Barraquer
Journal:  Int Ophthalmol Clin       Date:  1996

4.  A corneal flap technique for laser in situ keratomileusis. Human studies.

Authors:  I G Pallikaris; M E Papatzanaki; D S Siganos; M K Tsilimbaris
Journal:  Arch Ophthalmol       Date:  1991-12

5.  Laser in situ keratomileusis for myopia and astigmatism: 6 month results.

Authors:  D D Dulaney; R W Barnet; S A Perkins; G M Kezirian
Journal:  J Cataract Refract Surg       Date:  1998-06       Impact factor: 3.351

  5 in total