Literature DB >> 11189323

Quantitative real time measurement of iris configuration in human eyes.

N Wang1, M Lai, W Zhou.   

Abstract

PURPOSE: To evaluate intraobserver and interobserver reproducibility of real time measurement of iris morphology in living human eyes.
METHODS: Based on the platform of software (Autocad, version 12), we developed an ultrasound biomicroscopy (UBM) image assistant measuring system. By using the system, we can perform the iris configuration quantitative measurement in living eyes. The measuring parameters including: iris rest length, radius of iris curvature, and the thickness in different parts of iris. Ten anterior segment images of one normal individual were obtained by a single operator to evaluate the intraobserver reproducibility of image capture, and ten times measurement of one image were performed by a single operator to assess the reproducibility of image measurement. The measurement of three independent observers were compared to investigate interobserver reproducibility in quantitative measurement. Intraobserver and interobserver reproducibility of measurement were assessed by calculating the coefficient of variation for each individual observer and by using the F test to detect a difference among observers. The iris configuration of 96 subjects (192 eyes) were measured.
RESULTS: Intraobserver reproducibility was ranged from 0.9-4.9% in all measured parameters. Interobserver reproducibility for some of measured parameters varied considerably and was affected by subjective interpretative of visualized anatomic landmarks. The preliminary measured parameters in Chinese Show that iris rest length is 3.699 +/- 0.397 mm, radius of iris curvature is 9.101 +/- 1.408 mm, the average thickness of iris is 0.406 +/- 0.042 mm.
CONCLUSION: The intraobserver reproducibility and the measured accuracy can fit the requisition of the ocular biometry and of the ocular physiology, pathophysiology, and pharmacology study. The method supply a new assistance for UBM image measurement.

Entities:  

Mesh:

Year:  1997        PMID: 11189323

Source DB:  PubMed          Journal:  Yan Ke Xue Bao        ISSN: 1000-4432


  1 in total

1.  Iris ultrastructure in patients with synechiae as revealed by in vivo laser scanning confocal microscopy : In vivo iris ultrastructure in patients with Synechiae by Laser Scanning Confocal Microscopy.

Authors:  Ming Li; Hongbo Cheng; Ping Guo; Chun Zhang; Song Tang; Shusheng Wang
Journal:  BMC Ophthalmol       Date:  2016-04-26       Impact factor: 2.209

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.