Literature DB >> 11188996

Endothelial replacement without surface corneal incisions or sutures: topography of the deep lamellar endothelial keratoplasty procedure.

M A Terry1, P J Ousley.   

Abstract

PURPOSE: To evaluate the immediate postoperative corneal topography after the deep lamellar endothelial keratoplasty procedure.
METHODS: Eight eye bank eyes underwent deep lamellar endothelial keratoplasty through a 9.0-mm limbal incision replacing the central 7.0 mm of posterior stroma and endothelium through the lamellar pocket wound. Orbscan topography was performed before and after surgery, and simulated keratometry readings and central corneal diopter power were recorded. The change in astigmatism and corneal power from preoperative to postoperative readings was then determined.
RESULTS: The net change in corneal astigmatism averaged 0.4+/-0.5 diopters (range, -0.1 to 1.1 diopters). The net change in corneal power averaged -0.2+/-0.4 diopters of flattening (range, -0.9 to +0.2 diopters). Neither the astigmatism nor the corneal power levels after this surgery were significantly different from the preoperative topography (p = 0.22 and 0.27, respectively).
CONCLUSIONS: The deep lamellar endothelial keratoplasty procedure, with its absence of corneal surface incisions or sutures, has no significant effect on immediate postoperative corneal topography. The potential advantages of this procedure over penetrating keratoplasty in the treatment of endothelial dysfunction are considerable.

Entities:  

Mesh:

Year:  2001        PMID: 11188996     DOI: 10.1097/00003226-200101000-00002

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  11 in total

1.  Endothelial keratoplasty: clinical outcomes in the two years following deep lamellar endothelial keratoplasty (an American Ophthalmological Society thesis).

Authors:  Mark A Terry
Journal:  Trans Am Ophthalmol Soc       Date:  2007

Review 2.  Graft survival and endothelial outcomes in the new era of endothelial keratoplasty.

Authors:  Sanjay V Patel
Journal:  Exp Eye Res       Date:  2011-06-15       Impact factor: 3.467

3.  Endothelial keratoplasty: a comparison of complication rates and endothelial survival between precut tissue and surgeon-cut tissue by a single DSAEK surgeon.

Authors:  Mark A Terry
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

4.  [Reproducibility of femtosecond laser incisions for posterior lamellar keratoplasty in vitro].

Authors:  S Harlfinger; A Langenbucher; C Hofmann-Rummelt; B Seitz
Journal:  Ophthalmologe       Date:  2013-01       Impact factor: 1.059

5.  Engineered Basement Membranes for Regenerating the Corneal Endothelium.

Authors:  Rachelle N Palchesko; James L Funderburgh; Adam W Feinberg
Journal:  Adv Healthc Mater       Date:  2016-10-10       Impact factor: 9.933

6.  Impact of Donor Age on Corneal Endothelium-Descemet Membrane Layer Scroll Formation.

Authors:  Adam Bennett; Shahira Mahmoud; Donna Drury; H Dwight Cavanagh; James P McCulley; W Matthew Petroll; V Vinod Mootha
Journal:  Eye Contact Lens       Date:  2015-07       Impact factor: 2.018

7.  Slit-lamp technique of draining interface fluid following Descemet's stripping endothelial keratoplasty.

Authors:  Sathish Srinivasan; David S Rootman
Journal:  Br J Ophthalmol       Date:  2007-09       Impact factor: 4.638

8.  Case report: femtosecond laser-assisted small incision deep lamellar endothelial keratoplasty.

Authors:  Dong Hoon Lee; Tae Young Chung; Eui Sang Chung; Dimitri T Azar
Journal:  Korean J Ophthalmol       Date:  2008-03

9.  In vitro expansion of corneal endothelial cells on biomimetic substrates.

Authors:  Rachelle N Palchesko; Kira L Lathrop; James L Funderburgh; Adam W Feinberg
Journal:  Sci Rep       Date:  2015-01-22       Impact factor: 4.379

10.  Descemet stripping and endothelial keratoplasty in endothelial dysfunctions: three-month results in 75 eyes.

Authors:  Samar K Basak
Journal:  Indian J Ophthalmol       Date:  2008 Jul-Aug       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.