Literature DB >> 11182130

A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data.

K J Fischer1, T T Manson, H J Pfaeffle, M M Tomaino, S L Woo.   

Abstract

A method for measuring three-dimensional kinematics that incorporates the direct cross-registration of experimental kinematics with anatomic geometry from Computed Tomography (CT) data has been developed. Plexiglas registration blocks were attached to the bones of interest and the specimen was CT scanned. Computer models of the bone surface were developed from the CT image data. Determination of discrete kinematics was accomplished by digitizing three pre-selected contiguous surfaces of each registration block using a three-dimensional point digitization system. Cross-registration of bone surface models from the CT data was accomplished by identifying the registration block surfaces within the CT images. Kinematics measured during a biomechanical experiment were applied to the computer models of the bone surface. The overall accuracy of the method was shown to be at or below the accuracy of the digitization system used. For this experimental application, the accuracy was better than +/-0.1mm for position and 0.1 degrees for orientation for linkage digitization and better than +/-0.2mm and +/-0.2 degrees for CT digitization. Surface models of the radius and ulna were constructed from CT data, as an example application. Kinematics of the bones were measured for simulated forearm rotation. Screw-displacement axis analysis showed 0.1mm (proximal) translation of the radius (with respect to the ulna) from supination to neutral (85.2 degrees rotation) and 1.4mm (proximal) translation from neutral to pronation (65.3 degrees rotation). The motion of the radius with respect to the ulna was displayed using the surface models. This methodology is a useful tool for the measurement and application of rigid-body kinematics to computer models.

Entities:  

Mesh:

Year:  2001        PMID: 11182130     DOI: 10.1016/s0021-9290(00)00195-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles.

Authors:  Zhaochun Yang; Alexis C Wickwire; Richard E Debski
Journal:  Med Biol Eng Comput       Date:  2010-06-29       Impact factor: 2.602

2.  Validation of finite element predictions of cartilage contact pressure in the human hip joint.

Authors:  Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Christopher L Peters; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

3.  Development and validation of a kinematically-driven discrete element model of the patellofemoral joint.

Authors:  Jonathan A Gustafson; John J Elias; Richard E Debski; Shawn Farrokhi
Journal:  J Biomech       Date:  2019-03-28       Impact factor: 2.712

4.  High-speed X-ray video demonstrates significant skin movement errors with standard optical kinematics during rat locomotion.

Authors:  Jay M Bauman; Young-Hui Chang
Journal:  J Neurosci Methods       Date:  2009-11-10       Impact factor: 2.390

5.  Specimen-specific predictions of contact stress under physiological loading in the human hip: validation and sensitivity studies.

Authors:  Corinne R Henak; Ashley L Kapron; Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Jeffrey A Weiss
Journal:  Biomech Model Mechanobiol       Date:  2013-06-05

6.  The glenohumeral capsule should be evaluated as a sheet of fibrous tissue: a validated finite element model.

Authors:  Susan M Moore; Benjamin Ellis; Jeffrey A Weiss; Patrick J McMahon; Richard E Debski
Journal:  Ann Biomed Eng       Date:  2009-11-13       Impact factor: 3.934

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.