Transcutaneous determination of arterial oxygen tension.

A Fenner, R Müller, H G Busse, M Junge, J Wolfsdorf.   

Abstract

Arterial oxygen tension measurements were performed simultaneously using two different techniques: (1) the conventional method of analyzing a blood sample obtained from the radial artery by means of a Clark electrode and (2) a new method of transcutaneous oxygen tension recording using a newly developed surface electrode containing a built-in heating device to ensure optimal cutaneous perfusion at the site of measurement. Two groups of newborn infants were used as subjects: (1) 70 clinically healthy babies who were tested during normoxia and hyperoxia (breathing 80% to 100% oxygen) and (2) 20 sick preterm and term infants receiving inspired oxygen concentrations of between 21% and 100% during the measurement. Our results indicate a satisfactory accuracy for the transcutaneous oxygen tension measurements in normoxia and hyperoxia (percentage coefficient of variation, 15.9% and 24.1%, respectively). In hypoxia agreement between the two methods varies depending on the degree of circulatory derangement. Overall correlation coefficients were greater than 0.85 in each group.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1118209

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  8 in total

1.  Screen-printed transcutaneous oxygen sensor employing polymer electrolytes.

Authors:  Y Z Lam; J K Atkinson
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

2.  Effects of routine care procedures on transcutaneous oxygen in neonates: a quantitative approach.

Authors:  D A Danford; S Miske; J Headley; R M Nelson
Journal:  Arch Dis Child       Date:  1983-01       Impact factor: 3.791

3.  Arterial and transcutaneous oxygen tension measurement during hypotensive anaesthesia.

Authors:  T D Rafferty; M Durkin
Journal:  Ann R Coll Surg Engl       Date:  1983-01       Impact factor: 1.891

4.  Characteristics of transcutaneous oxygen tension monitors in normal adults and critically ill patients.

Authors:  S V Rithalia; A Rozkovec; J Tinker
Journal:  Intensive Care Med       Date:  1979-09       Impact factor: 17.440

5.  Acid-base parameters and alveolar-arterial oxygen tension gradients in healthy neonatal and postneonatal infants.

Authors:  A Fenner; H G Busse; M Junge; R Müller
Journal:  Eur J Pediatr       Date:  1976-04-06       Impact factor: 3.183

6.  Transcutaneous PO2 monitoring in infants with cyanotic congenital heart disease treated with prostaglandin E1.

Authors:  K J Kimble; R L Ariagno; P Pitlick
Journal:  Pediatr Cardiol       Date:  1983 Apr-Jun       Impact factor: 1.655

7.  [Transcutaneous measurement of oxygen partial pressure in the preoperative determination of the amputation level in the arterial occlusive disease of the lower extremity].

Authors:  S Cyba-Altunbay; J F Vollmar; M Waurick
Journal:  Langenbecks Arch Chir       Date:  1985

Review 8.  Management of the pediatric patient after cardiac surgery.

Authors:  G Lister
Journal:  Yale J Biol Med       Date:  1984 Jan-Feb
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.