Literature DB >> 11175274

The effects of different image file formats and image-analysis software programs on dental radiometric digital evaluations.

P Gürdal1, C F Hildebolt, B G Akdeniz.   

Abstract

OBJECTIVES: To determine if variations in radiodensity data are introduced by lossy Joint Photographic Experts Group (JPEG) compression and/or the use of three software programs.
METHODS: An occlusal film with an aluminium step wedge was exposed, processed and digitized under standard conditions. Before the image was saved, the coordinates and the gray-scale value for each pixel in a 20 x 20 pixel area near the middle of the thickest step were recorded. These pixel coordinates and gray-scale values served as Truth 1. In addition, a digital simulated-radiographic image with assigned gray-scale values for each pixel was created and served as Truth 2. The digital data for the scanned radiograph and the simulated radiograph were saved as Tagged Image File Format (TIFF) and lossy JPEG files. Each file was opened with three software programs and the gray-scale values of homologous pixels were recorded. For these pixels in each image type, the mean gray-scale values and standard deviations were calculated. The pixel gray-scale values for each homologous pixel were also individually compared.
RESULTS: When the TIFF images were opened with the three software programs, one program resulted in gray-scale values that were not concordant with truth. All JPEG images resulted in gray-scale values that were not concordant with truth.
CONCLUSIONS: One software program added a column of 0s to data files. Lossy JPEG compression introduced potentially deleterious variations to radiodensity data, and at least two of the software programs performed JPEG image decompression differently.

Mesh:

Year:  2001        PMID: 11175274     DOI: 10.1038/sj/dmfr/4600570

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  4 in total

1.  Roundness variation in JPEG images affects the automated process of nuclear immunohistochemical quantification: correction with a linear regression model.

Authors:  Carlos López; Joaquín Jaén Martinez; Marylène Lejeune; Patricia Escrivà; Maria T Salvadó; Lluis E Pons; Tomás Alvaro; Jordi Baucells; Marcial García-Rojo; Xavier Cugat; Ramón Bosch
Journal:  Histochem Cell Biol       Date:  2009-08-04       Impact factor: 4.304

2.  Effects of image compression on automatic count of immunohistochemically stained nuclei in digital images.

Authors:  Carlos López; Marylène Lejeune; Patricia Escrivà; Ramón Bosch; Maria Teresa Salvadó; Lluis E Pons; Jordi Baucells; Xavier Cugat; Tomás Alvaro; Joaquín Jaén
Journal:  J Am Med Inform Assoc       Date:  2008-08-28       Impact factor: 4.497

3.  Clinical and radiographic evaluation of copolymerized Polylactic/polyglycolic acids as a bone filler in combination with a cellular dermal matrix graft around immediate implants.

Authors:  Mahitab M Soliman; Azza Abdulrahman Zaki; Hanaa Mohamed El Gazaerly; Ammar Al Shemmrani; Abd El Latif Sorour
Journal:  Int J Health Sci (Qassim)       Date:  2014-10

4.  Evaluation of diagnostic accuracy of conventional and digital periapical radiography, panoramic radiography, and cone-beam computed tomography in the assessment of alveolar bone loss.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Renata Hernandes Tonin
Journal:  Contemp Clin Dent       Date:  2014-07