Literature DB >> 11175171

Transvascular Imaging: Feasibility Study Using a Vector Phased Array Ultrasound Catheter.

Charles J. Bruce1, Douglas L. Packer, James B. Seward.   

Abstract

BACKGROUND: Transvascular imaging is defined as the acquisition of anatomic and functional information of structures lying beyond the confines of a vascular conduit within which the imaging device resides. Interrogating structures surrounding the vascular conduit is the subject of this feasibility study using a novel underblood, phased array ultrasound-tipped catheter.
METHODS: An intravascular catheter (10-F, 3.2-mm-diameter, four-way articulation) tipped with a 5.5- to 10-MHz frequency agile, vector phased array transducer with full Doppler capability (Sequoia, Acuson) was used. The imaging transducer has a wide range of tissue penetration (2 mm to >10 cm from the lens). The catheter was introduced via an 11-Fr femoral venous sheath into the inferior and superior vena cavae and right heart chambers. As the catheter was advanced, attention was directed to visualization of structures surrounding the vessel in which the catheter resided.
RESULTS: From the cavae and femoral vein the thoracic, abdominal and femoral arteries could be easily imaged. Anatomy that was visualized included the liver, hepatic veins, gallbladder, and mesenteric vessels. Normal and pathological anatomy and Doppler physiology could be readily appreciated. Doppler (i.e., pulsed- and continuous-wave, color flow, and tissue Doppler) fostered unique transvascular physiological hemodynamic and flow assessment.
CONCLUSION: Transvascular imaging is feasible in human subjects using this 10-Fr catheter tipped with a 5.5- to 10-MHz vector phased array transducer. Intravascular navigation to a desired location within the body and the performance of diagnostic or therapeutic procedures at a remote site under direct ultrasound visualization are possible. Full Doppler capability extends the concept of transvascular hemodynamic and physiological assessment.

Entities:  

Year:  1999        PMID: 11175171     DOI: 10.1111/j.1540-8175.1999.tb00086.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

Review 1.  Novel applications in catheter ablation.

Authors:  Sergio G Thal; Nassir F Marrouche
Journal:  J Interv Card Electrophysiol       Date:  2005-08       Impact factor: 1.900

2.  Real time quantification of low temperature radiofrequency ablation lesion size using phased array intracardiac echocardiography in the canine model: comparison of two dimensional images with pathological lesion characteristics.

Authors:  A Doi; M Takagi; I Toda; M Teragaki; M Yoshiyama; K Takeuchi; J Yoshikawa
Journal:  Heart       Date:  2003-08       Impact factor: 5.994

3.  Ultrasound-guided placement of a renal artery stent using an intracardiac probe for transvascular imaging.

Authors:  Marek Belohlavek; Panupong Jiamsripong; Eileen M McMahon; Theresa R Lombari; Lilach O Lerman
Journal:  Open Cardiovasc Med J       Date:  2011-11-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.