Literature DB >> 11169818

Metallic surgical instruments for interventional MRI procedures: evaluation of MR safety.

F G Shellock1.   

Abstract

This investigation evaluated metallic surgical instruments for magnetic resonance (MR) safety in association with a 1.5-Tesla/64-MHz MR system. Seven different instruments (mallet, bone punch, curette, Weil-Blakesley ethmoid forceps, suction cannula, septum speculum, and Kocher-Langenbeck retractor; Aesculap, Inc. (South San Francisco, CA) were tested for magnetic field interactions, heating, and generation of artifacts by using previously described techniques. Heating was evaluated for the septum speculum and Kocher-Langenbeck retractor by using a special gel-filled phantom and a fluoroptic thermometer to record temperatures immediately before and during MRI performed at a whole-body averaged SAR of 1.3 W/kg. Artifacts were assessed with the instruments placed inside of a gel-filled phantom and performing MRI using T1-weighted spin-echo and gradient-echo pulse sequences. Magnetic field interactions were relatively minor (deflection angles, 0 to 7 degrees; torque, 0 to +1), the highest temperature changes were < or = +0.8 degrees C, and the artifacts should not create substantial problems considering the "intended use" for these instruments. The findings of the MR safety tests indicated that the seven different metallic surgical instruments (Aesculap, Inc.) would be safe and acceptable for use in interventional MRI procedures performed with MR systems with static magnetic fields of 1.5 T or less. J. Magn. Reson. Imaging 2001;13:152-157. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11169818     DOI: 10.1002/1522-2586(200101)13:1<152::aid-jmri1023>3.0.co;2-c

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

Review 1.  Interventional and intraoperative MR: review and update of techniques and clinical experience.

Authors:  Thomas Schulz; Silvia Puccini; Jens-Peter Schneider; Thomas Kahn
Journal:  Eur Radiol       Date:  2004-10-06       Impact factor: 5.315

2.  MAPS - a Magic Angle Positioning System for Enhanced Imaging in High-Field Small-Bore MRI.

Authors:  Alexander Squires; Kevin C Chan; Leon C Ho; Ian A Sigal; Ning-Jiun Jan; Zion Tsz Ho Tse
Journal:  J Med Robot Res       Date:  2016-03-31

3.  Evaluation of the Rebound Hernia Repair device for laparoscopic hernia repair.

Authors:  Gonzalo Torres-Villalobos; Laura Sorcic; George R Ruth; Rafael Andrade; Luis A Martin-del-Campo; J Kyle Anderson
Journal:  JSLS       Date:  2010 Jan-Mar       Impact factor: 2.172

4.  A Simple and Inexpensive Stereotactic Guidance Frame for MRI-Guided Brain Biopsy in Canines.

Authors:  Alexander D Squires; Yabiao Gao; Sean F Taylor; Marc Kent; Zion Tsz Ho Tse
Journal:  J Med Eng       Date:  2014-05-18

5.  Development of clinical simultaneous SPECT/MRI.

Authors:  Brian F Hutton; Michele Occhipinti; Andre Kuehne; Domokos Máthé; Noémi Kovács; Helmar Waiczies; Kjell Erlandsson; Debora Salvado; Marco Carminati; Giovanni L Montagnani; Susan C Short; Luisa Ottobrini; Pieter van Mullekom; Claudio Piemonte; Tamas Bukki; Zoltan Nyitrai; Zoltan Papp; Kalman Nagy; Thoralf Niendorf; Irene de Francesco; Carlo Fiorini
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.