Literature DB >> 11168746

Subgingival polishing compared to scaling with steel curettes: a clinical pilot study.

T Kocher1, J König, P Hansen, A Rühling.   

Abstract

BACKGROUND: Recently, we have developed teflon-coated sonic scaler inserts which remove plaque without removing tooth substance; they polish subgingivally. In a preclinical test, we showed that these modified inserts remove plaque nearly as effectively as do conventional sonic scaler inserts. The present investigation was intended as a proof-of-principle of subgingival polishing. The aim was to study the effect of subgingival polishing on the resolution of gingival inflammation in comparison to conventional scaling.
MATERIAL AND METHODS: In 10 patients with moderate to advanced periodontal disease, who had at least 2 single-rooted teeth with a probing depth of >6 mm in each quadrant, all single-rooted teeth were subjected to one treatment regimen consisting of 2 instrumentation episodes (1st/2nd treatment): curette/curette, curette/teflon-coated sonic scaler, teflon-coated sonic scaler/teflon-coated sonic scaler, and an untreated control. The second treatment session was performed 3 months after the first instrumentation, and the final registration 3 months after the second instrumentation. Clinical measurements included probing depth, change of clinical attachment level, bleeding upon probing, and plaque scores.
RESULTS: Probing depth, attachment level, and bleeding scores were reduced in the 3 instrumentation groups versus the control group in the 1st period; in the 2nd period, no further change occurred. Subgingival polishing with teflon-coated sonic scaler inserts was slightly less effective than conventional scaling.
CONCLUSION: Subgingival polishing with teflon-coated sonic scaler inserts seems to be nearly as effective as conventional scaling. Thus, it may be the instrumentation of choice for maintenance treatment of residual pockets.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11168746     DOI: 10.1034/j.1600-051x.2001.028002194.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  6 in total

1.  Use of a continual sweep motion to compare air polishing devices, powders and exposure time on unexposed root cementum.

Authors:  Mandy L Herr; Ralph DeLong; Yuping Li; Scott A Lunos; Jill L Stoltenberg
Journal:  Odontology       Date:  2017-01-09       Impact factor: 2.634

2.  Influence of Different Proportions of External Irrigation During the Er,Cr:YSGG Laser Irradiation on Wear and Roughness of Root Surface.

Authors:  Guilherme José Pimentel Lopes de Oliveira; Felipe Eduardo Pinotti; Heglécia da Luz Carvalho; Cássio Rocha Scardueli; Rosemary Adriana Chiérici Marcantonio
Journal:  J Lasers Med Sci       Date:  2016-01-07

3.  Subgingival instrumentation to remove simulated plaque in vitro: influence of operators' experience and type of instrument.

Authors:  Christian Graetz; Falk Schwendicke; Anna Plaumann; Sebastian Rauschenbach; Claudia Springer; Maren Kahl; Sonja Sälzer; Christof E Dörfer
Journal:  Clin Oral Investig       Date:  2014-09-19       Impact factor: 3.573

4.  Efficacy versus health risks: An in vitro evaluation of power-driven scalers.

Authors:  Christian Graetz; Anna Plaumann; Jule Bielfeldt; Anica Tillner; Sonja Sälzer; Christof Edmund Dörfer
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

5.  Effects of Periodontal Endoscopy-Assisted Nonsurgical Treatment of Periodontitis: Four-Month Results of a Randomized Controlled Split-Mouth Pilot Study.

Authors:  Christian Graetz; Johanna Sentker; Miriam Cyris; Susanne Schorr; Claudia Springer; Karim M Fawzy El-Sayed
Journal:  Int J Dent       Date:  2022-01-17

6.  Longitudinal relationship between plasma reactive oxygen metabolites and periodontal condition in the maintenance phase of periodontal treatment.

Authors:  Tatsuya Machida; Takaaki Tomofuji; Daisuke Ekuni; Mayu Yamane; Toshiki Yoneda; Yuya Kawabata; Kota Kataoka; Naofumi Tamaki; Manabu Morita
Journal:  Dis Markers       Date:  2014-04-16       Impact factor: 3.434

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.