Literature DB >> 11168305

Coronary flow reserve: measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography.

M Saraste1, J Koskenvuo, J Knuuti, J Toikka, H Laine, P Niemi, H Sakuma, J Hartiala.   

Abstract

Detection of early vascular changes indicated by lowered coronary flow reserve (CFR) would allow early treatment and prevention of atherosclerosis. The purpose of this study was to test whether it is possible to reproducibly measure CFR with transthoracic Doppler echocardiography (TTE) in healthy volunteers. We measured CFR using dipyridamole infusion in ten healthy male volunteers with two methods: TTE and positron emission tomography (PET) with oxygen-15-labelled water (group A). However, CFR was assessed twice with TTE in eight healthy male volunteers (group B) to study the reproducibility of this method. We compared CFRs obtained using TTE flow measurements in the left anterior descending coronary artery (LAD) and PET flow measurements in the corresponding myocardial area. Coronary flow in LAD could be measured in all subjects using TTE. By TTE, an average CFR based on peak diastolic flow velocity (PDV) was 2.72 +/- 1.16, mean diastolic flow velocity (MDV) 2.56 +/- 1.06 and velocity time integral (VTI) 1.87 +/- 0.49. The results were reproducible in two repeated TTE studies (coefficient of variation in MDV 6.1 +/- 4.3%, n=8). By PET, CFR was 2.52 +/- 0.84. CFR assessed by TTE correlated closely with that measured by PET (MDV r=0.942, P<0.001; PDV r=0.912, P<0.002 and VTI r=0.888, P<0.006) and intraclass correlation was 0.929 (MDV) and tolerance limits for differences of CFRs was -0.78 to 0.72. We show that CFR measured by TTE has an excellent correlation with CFR measured by PET. We also found that TTE measurements of CFR were highly reproducible.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11168305     DOI: 10.1046/j.1365-2281.2001.00296.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  40 in total

1.  Estimation of coronary flow reserve: can SPECT compete with other modalities?

Authors:  G T Gullberg; E V Di Bella; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

2.  Coronary flow reserve is preserved in white-coat hypertension.

Authors:  D Erdogan; H Gullu; M Caliskan; I Yildirim; D Tok; H Muderrisoglu
Journal:  Heart       Date:  2005-12-30       Impact factor: 5.994

3.  MR-based coronary artery blood velocity measurements in patients without coronary artery disease.

Authors:  M Schiemann; F Bakhtiary; V Hietschold; A Koch; A Esmaeili; H Ackermann; A Moritz; T J Vogl; N D Abolmaali
Journal:  Eur Radiol       Date:  2006-01-13       Impact factor: 5.315

4.  Doppler estimation of reduced coronary flow reserve in mice with pressure overload cardiac hypertrophy.

Authors:  Craig J Hartley; Anilkumar K Reddy; Sridhar Madala; Lloyd H Michael; Mark L Entman; George E Taffet
Journal:  Ultrasound Med Biol       Date:  2008-02-06       Impact factor: 2.998

5.  Coronary flow reserve is impaired in subclinical hypothyroidism.

Authors:  Semra Baycan; Dogan Erdogan; Mustafa Caliskan; Baris Onder Pamuk; Ozgur Ciftci; Hakan Gullu; Aylin Yildirir; Nilgun D Guvener; Haldun Muderrisoglu
Journal:  Clin Cardiol       Date:  2007-11       Impact factor: 2.882

6.  Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches.

Authors:  Giovanni Storto; Andrea Soricelli; Teresa Pellegrino; Mario Petretta; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

7.  Impaired coronary flow reserve in obstructive sleep apnea and its improvement after continuous positive airway pressure therapy: a transthoracic Doppler echocardiographic study.

Authors:  Kikuko Obase; Hiroyuki Okura; Keiji Mouri; Tomoko Maehama; Akihiro Hayashida; Nozomi Watanabe; Yoji Neishi; Takahiro Kawamoto; Mikio Oka; Kiyoshi Yoshida
Journal:  J Echocardiogr       Date:  2010-12-08

8.  Measurement of coronary flow reserve by noninvasive cardiac imaging.

Authors:  Alberto Cuocolo; Mario Petretta; Andrea Soricelli
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06       Impact factor: 9.236

Review 9.  Doppler velocity measurements from large and small arteries of mice.

Authors:  Craig J Hartley; Anilkumar K Reddy; Sridhar Madala; Mark L Entman; Lloyd H Michael; George E Taffet
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-05-13       Impact factor: 4.733

10.  Nebivolol improves coronary flow reserve in patients with idiopathic dilated cardiomyopathy.

Authors:  Dogan Erdogan; Hakan Gullu; Mustafa Caliskan; Ozgur Ciftci; Semra Baycan; Aylin Yildirir; Haldun Muderrisoglu
Journal:  Heart       Date:  2006-10-25       Impact factor: 5.994

View more