When placing osseointegrated dental implants, the site, angulation and depth of implants can be designed using a computed tomography (CT) or conventional X-ray tomography. To correctly identify placement pre-surgically, various kinds of surgical templates have been proposed. Although it is thought to be important to use templates, no material has been published on their accuracy. The purpose of this study was to propose a method for evaluating the placement accuracy using a specific surgical template. Twenty-one implants were evaluated in 6 patients with mean age of 50.7 years. All implants were implanted by two step surgery in the posterior mandible. A surgical template based on the CT images and the abutment replica on the working models were used for the evaluation of the accuracy of implant placement. The difference between the proposed and actual directions was measured by a milling machine. The difference in the angles between the proposed direction and actual direction were from 0.5 degrees to 14.5 degrees. The average was 5.0 degrees, and there were 12 implants (57%) within 5.0 degrees. This study demonstrated the accuracy of the template described in this article.

Entities:  

Mesh:

Year:  2000        PMID: 11168232     DOI: 10.1034/j.1600-0501.2000.011005409.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

Review 1.  State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

Authors:  Maria Eugenia Guerrero; Reinhilde Jacobs; Miet Loubele; Filip Schutyser; Paul Suetens; Daniel van Steenberghe
Journal:  Clin Oral Investig       Date:  2006-02-16       Impact factor: 3.573

2.  Designing a custom made gauge device for application in the access hole correction in the dental implant surgical guide.

Authors:  Elnaz Moslehifard; Saeid Nokar
Journal:  J Indian Prosthodont Soc       Date:  2011-10-16

3.  Guided implant surgery on oral cancer patients: in vitro study.

Authors:  Marion Paris; Anne-Gaëlle Chaux-Bodard; René Gourmet; Thomas Fortin
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-27       Impact factor: 2.924

4.  The Effect of Implant Length and Diameter on Stress Distribution around Single Implant Placement in 3D Posterior Mandibular FE Model Directly Constructed Form In Vivo CT.

Authors:  Akikazu Shinya; Yoshiki Ishida; Daisuke Miura; Akiyoshi Shinya
Journal:  Materials (Basel)       Date:  2021-11-30       Impact factor: 3.623

5.  Dental implant location via surface scanner: a pilot study.

Authors:  Miao Zhou; Hui Zhou; Shu-Yi Li; Yuan-Ming Geng
Journal:  BMC Oral Health       Date:  2020-11-04       Impact factor: 2.757

  5 in total