Literature DB >> 11168204

Influence of multiple use of Timedur-titanium cannon drills: thermal response and scanning electron microscopic findings.

R M Jochum1, P A Reichart.   

Abstract

Multiple use of dental drills is known to raise drilling temperatures. Therefore, to minimize surgical trauma, well sharpened drills are recommended. In order to evaluate surgical trauma due to multiple use, 20 Timedur cannon drills (ZL-Duraplant-Implant-System) were used 51 times in an in vitro experimental setting using pigs' mandibles. Preparations of implant sites were performed with cannon drills at a maximum rotational speed of 1200 r.p.m. with low pressure and water irrigation. Drills were divided randomly into 3 groups and were treated differently after each preparation: 10 cannon drills were cleaned only with distilled water (group 1), 5 cannon drills were disinfected with Secudrill and autoclaved (group 2) and 5 cannon drills were cleaned with Instrument Detergent MIS 027 and autoclaved (group 3). Temperature measurements were performed with a NiCrNi thermocouple placed 0.5 mm from the drilling site. The width of the cutting edge of the cannon drills was repeatedly examined by scanning electron microscope (SEM). Results revealed that temperatures measured at all times were below the bone injuring level. Drills reused more than 40 times stood out with an increased number of higher temperatures. Only autoclaved drills showed an increased width of the cutting edges. From the present investigation it can be concluded that cannon drills of the ZL-Duraplant System should not be re-used more than 40 times.

Entities:  

Mesh:

Year:  2000        PMID: 11168204

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  12 in total

1.  Study of temperature variation in cortical bone during osteotomies with trephine drills.

Authors:  Sergio Alexandre Gehrke; Marcelo Khoury Pazetto; Sérgio de Oliveira; Stefano Corbella; Silvio Taschieri; Fábio E C Mardegan
Journal:  Clin Oral Investig       Date:  2014-01-08       Impact factor: 3.573

Review 2.  Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2014-02-18

3.  Effect of irrigation and stainless steel drills on dental implant bed heat generation.

Authors:  B Bullon; E F Bueno; M Herrero; A Fernandez-Palacin; J V Rios; P Bullon; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

4.  Retained broken implants in the craniomaxillofacial skeleton.

Authors:  Vigneswaran Nallathamby; Hanjing Lee; Yap Yan Lin; Jane Lim; Wei Chen Ong; Thiam-Chye Lim
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-03-11

Review 5.  Drilling of bone: A comprehensive review.

Authors:  Rupesh Kumar Pandey; S S Panda
Journal:  J Clin Orthop Trauma       Date:  2013-01-18

Review 6.  Heat Development During Medical Drilling: Influencing Factors and Examination Methods - Overview and First Results.

Authors:  Ole Jung; Carolin Lindner; Sven Pantermehl; Mike Barbeck
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

7.  In Vitro Study on Bone Heating during Drilling of the Implant Site: Material, Design and Wear of the Surgical Drill.

Authors:  Juan Carlos Bernabeu-Mira; Hilario Pellicer-Chover; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Materials (Basel)       Date:  2020-04-19       Impact factor: 3.623

8.  Recommended Drilling Parameters of Tungsten Carbide Round Drills for the Most Optimal Bone Removals in Oral Surgery.

Authors:  József Szalma; Ole Klein; Bálint Viktor Lovász; Edina Lempel; Sára Jeges; Lajos Olasz
Journal:  Biomed Res Int       Date:  2018-11-19       Impact factor: 3.411

9.  Clinical Influence of Micromorphological Structure of Dental Implant Bone Drills.

Authors:  Gaetano Marenzi; Josè Camilla Sammartino; Giuseppe Quaremba; Vincenzo Graziano; Andrea El Hassanin; Med Erda Qorri; Gilberto Sammartino; Vincenzo Iorio-Siciliano
Journal:  Biomed Res Int       Date:  2018-06-06       Impact factor: 3.411

10.  In-situ tool wear monitoring and its effects on the performance of porcine cortical bone drilling: a comparative in-vitro investigation.

Authors:  Vishal Gupta; Pulak M Pandey
Journal:  Mech Adv Mater Mod Process       Date:  2017-01-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.