Literature DB >> 11167476

Clinical evaluation of the Mapleson theoretical ideal fresh gas flow sequence at the start of low-flow anaesthesia with isoflurane, sevoflurane and desflurane.

P C Ip-Yam1, M H Goh, Y H Chan, C F Kong.   

Abstract

Mapleson used a computer spreadsheet model to predict the theoretical ideal fresh gas flow sequence at the start of low-flow anaesthesia. The aim was to increase the end-expired partial pressure of inhalational agent (PE'an) to one minimum alveolar concentration (MAC) as quickly as practicable and then to keep it constant. Ninety adult patients undergoing elective tonsillectomy under general anaesthesia were randomly allocated to one of three groups (n = 30) to receive isoflurane, sevoflurane or desflurane in oxygen. Fresh gas flow and vaporiser settings as specified by Mapleson were followed in all cases except that the maximum setting for desflurane was 18% (2.7 MAC instead of 3 MAC). Recordings of PE'an were made at 1, 2, 3, 4, 5, 7, 10, 15 and 20 min. Mean values of PE'an exceeded 1 MAC by 2 min in all three groups and remained above this value throughout. Each group's PE'an measurements were divided by their respective 1-MAC value. A simple two-level model (with patients at level 2 and time at level 1), with measurements at 1 min excluded, showed that the fitted value at 2 min and the time-weighted mean for 2-20 min for PE'iso (1.042 [95% CI 0.980-1.104] and 1.044 [0.984-1.104], respectively) were not significantly different from its 1-MAC value, whereas those of the PE'sevo (1.169 [1.119-1.219] and 1.143 [1.119-1.219]) and PE'des (1.305 [1.261-1.349] and 1.140 [1.098-1.182]) were significantly higher than their respective 1-MAC values. The Mapleson concept of an initial high fresh gas flow and high vaporiser settings, followed first by reduced high fresh gas flow, as followed in this clinical study, results in PE'an values close to or slightly higher than predicted in the spreadsheet model.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11167476     DOI: 10.1046/j.1365-2044.2001.01835.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  Effects of Minimal Flow Sevoflurane or Desflurane Anaesthesia on Hemodynamic Parameters, Body Temperature and Anaesthetic Consumption.

Authors:  Duygu Taşkın; Ender Gedik; Zeynep Kayhan
Journal:  Turk J Anaesthesiol Reanim       Date:  2020-05-05

2.  Mathematical method to build an empirical model for inhaled anesthetic agent wash-in.

Authors:  Jan Fa Hendrickx; Harry Lemmens; Sofie De Cooman; André Aj Van Zundert; René Ej Grouls; Eric Mortier; Andre M De Wolf
Journal:  BMC Anesthesiol       Date:  2011-06-24       Impact factor: 2.217

3.  1-1-12 one-step wash-in scheme for desflurane-nitrous oxide low-flow anesthesia: rapid and predictable induction.

Authors:  Thepakorn Sathitkarnmanee; Sirirat Tribuddharat; Chakthip Suttinarakorn; Duangthida Nonlhaopol; Maneerat Thananun; Wilawan Somdee; Sunchai Theerapongpakdee
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.