Literature DB >> 11167332

Contrast-enhanced thoracic 3D-MR angiography in infants and children.

C Holmqvist1, F Ståhlberg, S Laurin.   

Abstract

PURPOSE: To optimise breath-hold contrast-enhanced MR angiography (MRA) in infants and children with suspected congenital heart or thoracic vessel malformation.
MATERIAL AND METHODS: Thirty-nine children (median age 1 year) were examined, using five different ultrafast MRA sequences with a TR between 3.2 and 5.0 ms and the contrast agent meglumine gadoterate. A test injection was used to determine contrast travel time. Different parameters for contrast injection were evaluated. Signal-to-noise ratio (SNR) measurements were performed and image quality and injection timing were evaluated.
RESULTS: MRA was successful in all patients and image quality was considered very good in 52%. Adequate SNR was achieved with no significant differences between the MR sequences. SNR decreased only 25-30% between subsequent scans. The mean contrast dose was 0.23 mmol/kg. The mean scan time was 12.5 +/- 3.8 s; the shorter scan times made dynamic examinations possible with high temporal resolution. Highest spatial resolution was obtained with TR 4.6/5.0 sequences.
CONCLUSION: A contrast dose of 0.2 mmol/kg b.w. is recommended with an injection rate of 0.5 to 1.2 ml/s, depending on patient size and scan time. The scan delay time should equal the contrast travel time for optimal vessel enhancement. In the future, contrast-enhanced MRA may be a potential alternative to angiocardiography in infants and children.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11167332     DOI: 10.1080/028418501127346233

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.701


  4 in total

Review 1.  Magnetic resonance angiography of the body in pediatric patients: experience with a contrast-enhanced time-resolved technique.

Authors:  Taylor Chung
Journal:  Pediatr Radiol       Date:  2004-06-22

2.  Interrupted aortic arch in a neonate: multidetector CT diagnosis.

Authors:  Asli Cinar; Mithat Haliloglu; Tevfik Karagoz; Musturay Karcaaltincaba; Alpay Celiker; Gulsevin Tekinalp
Journal:  Pediatr Radiol       Date:  2004-09-17

3.  Contrast-enhanced magnetic resonance angiography of the great arteries in patients with congenital heart disease: an accurate tool for planning catheter-guided interventions.

Authors:  Emanuela R Valsangiacomo Büchel; Stefano DiBernardo; Urs Bauersfeld; Felix Berger
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

4.  Role and effectiveness of cardiovascular magnetic resonance in the diagnosis, preoperative evaluation and follow-up of patients with congenital heart diseases.

Authors:  L Lovato; A Giardini; C La Palombara; V Russo; V Gostoli; G Gargiulo; F M Picchio; R Fattori
Journal:  Radiol Med       Date:  2007-07-23       Impact factor: 6.313

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.