Literature DB >> 11165866

Dislocation of a plate-haptic silicone intraocular lens into the anterior chamber.

A Faucher1, D S Rootman.   

Abstract

Posterior dislocation is a well-described complication of plate-haptic intraocular lenses (IOLs). It usually occurs after an opening in the posterior capsule, either intraoperatively or after a neodymium: YAG capsulotomy occurs. We report a case of anterior luxation of a plate-haptic silicone IOL occurring 4 months after uneventful cataract surgery. This case emphasizes the need for a small and continuous capsulorhexis as well as in-the-bag implantation of plate-haptic IOLs.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11165866     DOI: 10.1016/s0886-3350(00)00497-1

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  3 in total

1.  Late posterior subluxation of rollable intraocular lens after an uneventful microphacoemulsification cataract surgery.

Authors:  Aditya S Kelkar; Jai A Kelkar; Shreekant B Kelkar; Aarofil I Shaikh
Journal:  Indian J Ophthalmol       Date:  2010 Jul-Aug       Impact factor: 1.848

2.  Bilateral recurrent dislocation of plate haptic intraocular lens.

Authors:  Arvind Venkataraman; Navin V Jayakumar; Preethi Bojan
Journal:  Indian J Ophthalmol       Date:  2011 Jul-Aug       Impact factor: 1.848

3.  Authors' reply.

Authors:  Aditya S Kelkar; Jai A Kelkar; Shreekant B Kelkar; Devanshi Bhanushali
Journal:  Indian J Ophthalmol       Date:  2014-06       Impact factor: 1.848