Literature DB >> 11159238

Online monitoring of air quality at the postanesthetic care unit by proton-transfer-reaction mass spectrometry.

J Rieder1, P Prazeller, M Boehler, P Lirk, W Lindinger, A Amann.   

Abstract

The subthreshold exposure to trace anesthetic gases is not associated with considerable risk of adverse health effects. Online control of ambient air exchange at the postoperative workplace may help in supervising air quality and lead to cost reduction. A proton-transfer-reaction mass spectrometer system was used for online monitoring of volatile organic compounds, especially anesthetic gases. The mean exposure to sevoflurane and isoflurane at the urological postanesthesia care unit (PACU) was 15.9 and 9.5 parts per billion, respectively. Sevoflurane and isoflurane concentrations at the urological PACU showed a patient turnover-dependent burden during our investigation period. Because modern PACUs have a high ventilation capacity, the 24-h occupational burden by anesthetic gases at the PACU is relatively low. Monitoring and controlling of ambient air by automatic built-in alarm systems would be useful for quality control of the postoperative workplace. Moreover, energy costs of ventilation systems could be reduced by coupling ventilation capacity to the effective exposure.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11159238     DOI: 10.1097/00000539-200102000-00021

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  Improvement of bioprocess monitoring: development of novel concepts.

Authors:  Franz Clementschitsch; Karl Bayer
Journal:  Microb Cell Fact       Date:  2006-05-22       Impact factor: 5.328

2.  Multi-capillary column-ion mobility spectrometry (MCC-IMS) as a new method for the quantification of occupational exposure to sevoflurane in anaesthesia workplaces: an observational feasibility study.

Authors:  Nils Kunze; Cathrin Weigel; Wolfgang Vautz; Katrin Schwerdtfeger; Melanie Jünger; Michael Quintel; Thorsten Perl
Journal:  J Occup Med Toxicol       Date:  2015-03-27       Impact factor: 2.646

3.  Elimination characteristics of post-operative isoflurane levels in alveolar exhaled breath via PTR-MS analysis.

Authors:  R Fernández Del Río; M E O'Hara; P Pemberton; T Whitehouse; C A Mayhew
Journal:  J Breath Res       Date:  2016-10-12       Impact factor: 3.262

Review 4.  Contemporary Research Progress on the Detection of Polycyclic Aromatic Hydrocarbons.

Authors:  Yan Zhang; Limin Yuan; Shuli He; Huilin Tao; Wenlian Xie; Xinyu Zhang; Xiaolu Ren; Tao Jiang; Lihong Li; Zhiqiang Zhu
Journal:  Int J Environ Res Public Health       Date:  2022-02-27       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.