Literature DB >> 11157881

Manifest refraction versus autorefraction for patients with subfoveal choroidal neovascularization.

P R Orr1, L D Cramer, B S Hawkins, N M Bressler.   

Abstract

PURPOSE: To compare the results from manifest refraction using trial lenses and a standard visual acuity protocol to results from autorefraction for obtaining refractive error and best corrected visual acuity in patients enrolled in a randomized clinical trial.
METHODS: During a 4-month period, 29 patients with subfoveal choroidal neovascularization (CNV), who were enrolled in the Submacular Surgery Trials (SSTs) Pilot Study at the Wilmer Ophthalmological Institute, gave verbal consent to participate in this study. Best corrected visual acuity was obtained using Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity charts and standardized room lighting after performance of manifest refraction, according to the SST protocol, and autorefraction. Refractive error (spherical equivalent) and visual acuity scores were obtained in both eyes of all patients.
RESULTS: On average, manifest refraction gave a spherical equivalent that was 1.04 D more plus than autorefraction (95% limits of agreement = 0.74, 1.34). On average, the visual acuity score was 1.5 letters better after manifest refraction than after autorefraction (95% limits of agreement = 0, 3.0). The comparison of the two methods of refraction was subdivided according to visual acuity level and eye disease (age-related macular degeneration or ocular histoplasmosis syndrome).
CONCLUSIONS: Despite large differences in spherical equivalent between manifest refraction and autorefraction, the visual acuity scores were close (mean difference, 1.5 letters). Other studies comparing subjective refraction and autorefraction have shown similar results. Autorefraction in patients with subfoveal CNV may be a satisfactory alternative to manifest refraction in clinical trials and field studies in which best corrected visual acuity is of interest.

Entities:  

Mesh:

Year:  2001        PMID: 11157881

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  3 in total

1.  Visual acuity testing using autorefraction or pinhole occluder compared with a manual protocol refraction in individuals with diabetes.

Authors:  Jennifer K Sun; Lloyd Paul Aiello; Jerry D Cavallerano; Margaret Stockman; Kellee M Miller; Haijing Qin; Roy W Beck; Adam R Glassman
Journal:  Ophthalmology       Date:  2010-10-14       Impact factor: 12.079

2.  Trial frame refraction versus autorefraction among new patients in a low-vision clinic.

Authors:  Dawn K DeCarlo; Gerald McGwin; Karen Searcey; Liyan Gao; Marsha Snow; John Waterbor; Cynthia Owsley
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-01-02       Impact factor: 4.799

3.  Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.

Authors:  Keyvan Shirzadi; Kourosh Shahraki; Emad Yahaghi; Ali Makateb; Keivan Khosravifard
Journal:  Med Arch       Date:  2016-07-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.