Literature DB >> 11157188

Evaluation of the TriSpan neck bridge device for the treatment of wide-necked aneurysms: an experimental study in canines.

A S Turk1, A H Rappe, F Villar, R Virmani, C M Strother.   

Abstract

BACKGROUND AND
PURPOSE: Many wide-necked aneurysms are difficult or impossible to treat with the Guglielmi detachable coil (GDC). The purpose of this study was to evaluate the use of a neck bridging device, the TriSpan coil, in combination with standard GDCs for the treatment of wide-necked aneurysms in an experimental canine aneurysm model.
METHODS: Of 24 experimental aneurysms in 12 animals, 19 (7 lateral and 12 terminal) were treated with the TriSpan coil in conjunction with standard GDCs. Digital subtraction angiography (DSA) was performed on all animals immediately after treatment. In 6 animals, follow-up DSA and histological evaluation were performed 4 weeks after treatment. In the remaining 6, DSA was done at both 90 and 180 days after treatment. Histological evaluation was done immediately after the 180-day angiographic evaluation.
RESULTS: The TriSpan was easy to use in conjunction with the standard GDC. Because of their geometry, some lateral aneurysms were difficult or impossible to treat with this device. Greater than 90% aneurysm occlusion was obtained in all 19 aneurysms. In no instance was there evidence of coil migration, herniation, or aneurysm recanalization. Histological evaluation of the tissue surrounding the TriSpan coil showed tissue responses similar to that seen with standard GDCs.
CONCLUSIONS: These results show that the TriSpan coil in conjunction with standard GDCs can be used safely and effectively for the treatment of wide-necked aneurysms in this canine model. Positioning and deployment of the neck bridge in aneurysms having an acute angle with the long axis of their parent artery are difficult or impossible. It is likely that this device, used in conjunction with the standard GDC, will allow treatment of some wide-necked aneurysms that are not treatable with the GDC alone.

Entities:  

Mesh:

Year:  2001        PMID: 11157188     DOI: 10.1161/01.str.32.2.492

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  7 in total

1.  Use of the trispan device to assist coil embolization of high-flow arteriovenous fistulas.

Authors:  Alain Weill; Daniel Roy; Stavros A Georganos; François Guilbert; Jean Raymond
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

2.  Transvenous coil treatment of a type a carotid cavernous fistula in association with transarterial trispan coil protection.

Authors:  Luca Remonda; Susanne Beatrice Frigerio; Robert Bühler; Gerhard Schroth
Journal:  AJNR Am J Neuroradiol       Date:  2004-04       Impact factor: 3.825

3.  A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion.

Authors:  Thomas Liebig; Hans Henkes; Jörg Reinartz; Elina Miloslavski; Dietmar Kühne
Journal:  Neuroradiology       Date:  2006-06-07       Impact factor: 2.804

4.  Endovascular coil occlusion of intracranial aneurysms assisted by a novel self-expandable nitinol microstent (neuroform).

Authors:  H Henkes; A Bose; S Felber; E Miloslavski; E Berg-Dammer; D Kühne
Journal:  Interv Neuroradiol       Date:  2004-10-20       Impact factor: 1.610

5.  Endovascular treatment of experimental wide neck aneurysms: comparison of results using coils or cyanoacrylate with the assistance of an aneurysm neck bridge device.

Authors:  Jean Raymond; Igor Salazkin; Stavros Georganos; François Guilbert; Anne-Cécile Desfaits; Guylaine Gevry; Alain Weill; Daniel Roy
Journal:  AJNR Am J Neuroradiol       Date:  2002 Nov-Dec       Impact factor: 3.825

6.  Analysis of clinical and radiological outcomes in microsurgical and endovascular treatment of basilar apex aneurysms.

Authors:  Sung-Chul Jin; Jae Sung Ahn; Byung-Duk Kwun; Do-Hoon Kwon
Journal:  J Korean Neurosurg Soc       Date:  2009-04-30

7.  Evaluation of a neck-bridge device to assist endovascular treatment of wide-neck aneurysms of the anterior circulation.

Authors:  K De Keukeleire; P Vanlangenhove; L Defreyne
Journal:  AJNR Am J Neuroradiol       Date:  2007-10-10       Impact factor: 3.825

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.