R Toda1, Y Moriyama, M Yamashita, Y Iguro, H Matsumoto, G Yotsumoto. 1. Second Department of Surgery, Faculty of Medicine, Kagoshima University, and National Minami Kyushu Chuoh Hospital, Japan. toda@med6.kufm.kagoshima-u.ac.jp
Abstract
BACKGROUND: Surgical repair of adult patent ductus arteriosus is more hazardous than when performed on young patients. METHODS: Nine adult patent ductus arteriosus patients underwent surgical repair between January 1986 and December 1998. There were 3 male and 6 female patients (mean age 55.0 years). The ratio of pulmonary blood flow to systemic flow was 2.40 +/- 0.95, and pulmonary arterial pressure was 56.0 +/- 26.4 mm Hg. The operation was performed using transpulmonary approach under total cardiopulmonary bypass. Balloon occlusion method was also utilized. RESULTS: Direct closure was made in 5 and patch closure in 4 patients. Cardiopulmonary bypass and balloon occlusion were safely established. Cardioplegic arrest was not required in the 2 most recent patients. No operative death has occurred. Pulmonary arterial systolic pressure decreased to 35.3 +/- 6.6 mm Hg at 6 months after operation. The mean follow-up period for all patients is 55 months. To date, neither recannalization of the ductus nor pseudoaneurysm has been recognized. CONCLUSIONS: Cardiopulmonary bypass with balloon occlusion provides a safe operation for adult patients with complicated patent ductus arteriosus.
BACKGROUND: Surgical repair of adult patent ductus arteriosus is more hazardous than when performed on young patients. METHODS: Nine adult patent ductus arteriosus patients underwent surgical repair between January 1986 and December 1998. There were 3 male and 6 female patients (mean age 55.0 years). The ratio of pulmonary blood flow to systemic flow was 2.40 +/- 0.95, and pulmonary arterial pressure was 56.0 +/- 26.4 mm Hg. The operation was performed using transpulmonary approach under total cardiopulmonary bypass. Balloon occlusion method was also utilized. RESULTS: Direct closure was made in 5 and patch closure in 4 patients. Cardiopulmonary bypass and balloon occlusion were safely established. Cardioplegic arrest was not required in the 2 most recent patients. No operative death has occurred. Pulmonary arterial systolic pressure decreased to 35.3 +/- 6.6 mm Hg at 6 months after operation. The mean follow-up period for all patients is 55 months. To date, neither recannalization of the ductus nor pseudoaneurysm has been recognized. CONCLUSIONS: Cardiopulmonary bypass with balloon occlusion provides a safe operation for adult patients with complicated patent ductus arteriosus.
Authors: Michal Galeczka; Malgorzata Szkutnik; Jacek Bialkowski; Sebastian Smerdzinski; Mateusz Knop; Adam Sukiennik; Roland Fiszer Journal: J Interv Cardiol Date: 2020-04-29 Impact factor: 2.279