Literature DB >> 11155535

[Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation].

H Abdul-Khaliq1, D Troitzsch, F Berger, P E Lange.   

Abstract

Using a dual channel near infrared (NIR) in vivo optical spectroscopy (INVOS) system (INVOS 3100A, Somanetics Corp. Troy, MI, USA) we investigated the relationship between jugular venous oxygen saturation (SjvO2) and regional cerebral oxygen saturation (rSO2) in 30 infants and children (mean age 4.5 years) with congenital heart disease undergoing cardiac catheterisation. The NIRS-SomaSensor (emitter and dual receiver probe) was applied at a standardised right fronto-temporal location (over the right frontal cortex) on the infant's head and covered with an adhesive flexible bandage. Using NIR light (730 and 810 nm) and two source-detector spacings (3 and 4 cm from the transmitter), percentage values of rSO2 were calculated from detected haemoglobin saturations. Simultaneously, jugular venous oxygen saturation (SjvO2) monitoring was performed via a catheter placed in the right internal jugular vein with its tip positioned in the jugular bulb, as verified by fluoroscopy. To compare the reliability of NIRS measurement characteristics, jugular venous blood was analysed for SjvO2 as a reference measure of global cerebral oxygenation, by co-oximetry (OSM3-Hemoximeter, Radiometer Copenhagen, Denmark). Other measured variables included pulse oximetry, arterial blood pressure, and venous and arterial oxygen saturations. Over a jugular venous oxygen saturation range of 31-83%, a significant positive linear correlation was found between rSO2 (NIRS measurement) and SjvO2 (jugular bulb oximetry) (r = 0.93, p < 0.001). No significant correlation was observed between rSO2 values and arterial blood saturation or pulse oximetry. The quantitative correlation between rSO2 (haemoglobin oxygenation in a small hemi-elliptical area of the brain) and reference SjvO2 measurement (method for monitoring global cerebral oxygenation) suggests that NIRS measurement with subtraction algorithm should identify predominantly intracranial saturation in the pediatric age group, and will tend to reflect global oxygenation under physiological conditions. Transcranial oximetry using dual receiving channel NIRS offers a noninvasive, real-time, reliable and practicable means of monitoring cerebral haemoglobin oxygenation changes infants and children with cyanotic and noncyanotic congenital heart disease.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11155535     DOI: 10.1515/bmte.2000.45.11.328

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  22 in total

Review 1.  In vivo validation of cerebral near-infrared spectroscopy: a review.

Authors:  Amalie la Cour; Gorm Greisen; Simon Hyttel-Sorensen
Journal:  Neurophotonics       Date:  2018-11-27       Impact factor: 3.593

2.  Non-invasive estimation of jugular venous oxygen saturation: a comparison between near infrared spectroscopy and transcutaneous venous oximetry.

Authors:  Douglas A Colquhoun; Jason M Tucker-Schwartz; Marcel E Durieux; Robert H Thiele
Journal:  J Clin Monit Comput       Date:  2012-04       Impact factor: 2.502

3.  Does treatment of patent ductus arteriosus with cyclooxygenase inhibitors affect neonatal regional tissue oxygenation?

Authors:  Mayoor Bhatt; Anna Petrova; Rajeev Mehta
Journal:  Pediatr Cardiol       Date:  2012-04-01       Impact factor: 1.655

4.  Low renal oximetry correlates with acute kidney injury after infant cardiac surgery.

Authors:  Gabe E Owens; Karen King; James G Gurney; John R Charpie
Journal:  Pediatr Cardiol       Date:  2010-11-19       Impact factor: 1.655

5.  Intraoperative cerebral oxygenation, oxidative injury, and delirium following cardiac surgery.

Authors:  Marcos G Lopez; Pratik Pandharipande; Jennifer Morse; Matthew S Shotwell; Ginger L Milne; Mias Pretorius; Andrew D Shaw; L Jackson Roberts; Frederic T Billings
Journal:  Free Radic Biol Med       Date:  2016-12-27       Impact factor: 7.376

Review 6.  Near-Infrared Spectroscopy in the Monitoring of Adult Traumatic Brain Injury: A Review.

Authors:  David J Davies; Zhangjie Su; Michael T Clancy; Samuel J E Lucas; Hamid Dehghani; Ann Logan; Antonio Belli
Journal:  J Neurotrauma       Date:  2015-04-17       Impact factor: 5.269

7.  Preserved Cerebral Oxygenation with Worsening Global Myocardial Strain during Pediatric Chronic Hemodialysis.

Authors:  Alexandra Idrovo; Ricardo Pignatelli; Robert Loar; Asela Nieuwsma; Jessica Geer; Catharina Solomon; Sarah Swartz; Nancy Ghanayem; Ayse Akcan-Arikan; Poyyapakkam Srivaths
Journal:  J Am Soc Nephrol       Date:  2021-09-13       Impact factor: 10.121

8.  Central venous oxygen saturation and blood lactate levels during cardiopulmonary bypass are associated with outcome after pediatric cardiac surgery.

Authors:  Marco Ranucci; Giuseppe Isgrò; Concetta Carlucci; Teresa De La Torre; Stefania Enginoli; Alessandro Frigiola
Journal:  Crit Care       Date:  2010-08-04       Impact factor: 9.097

Review 9.  Current monitoring and innovative predictive modeling to improve care in the pediatric cardiac intensive care unit.

Authors:  Mary K Olive; Gabe E Owens
Journal:  Transl Pediatr       Date:  2018-04

10.  Non-invasive optical neuromonitoring of the temperature-dependence of cerebral oxygen metabolism during deep hypothermic cardiopulmonary bypass in neonatal swine.

Authors:  Tiffany S Ko; Constantine D Mavroudis; Wesley B Baker; Vincent C Morano; Kobina Mensah-Brown; Timothy W Boorady; Alexander L Schmidt; Jennifer M Lynch; David R Busch; Javier Gentile; George Bratinov; Yuxi Lin; Sejin Jeong; Richard W Melchior; Tami M Rosenthal; Brandon C Shade; Kellie L Schiavo; Rui Xiao; J William Gaynor; Arjun G Yodh; Todd J Kilbaugh; Daniel J Licht
Journal:  J Cereb Blood Flow Metab       Date:  2018-10-30       Impact factor: 6.200

View more