Elucidation of accuracy in calibration of MR signal intensity based on transmission amplitude method.

T Yamamoto1, T Nambu, H Date, K Miyasaka.   

Abstract

To calibrate magnetic resonance (MR) signal intensity that depends on radio frequency (RF) coil loading, the transmission amplitude (TRA) for the excitation in the transmit-receive RF coil has been used as a good index in the so-called TRA method. As this TRA method needs neither an internal reference nor an additional external reference for the calibration, its accuracy is free from reference measurements. This study elucidated the calibration accuracy of MR signal intensities based on the TRA method. A cylindrical gel phantom was used for accuracy measurements with a 1.5-T MRI unit with conventional T1 imaging as a simple pulse sequence for various loading conditions. The brain parenchyma of eight healthy volunteers also showed calibrated MR signal deviations. The error of the phantom calibration measurements was 2.18% (S.D.%). The background noise intensity of images was theoretically derived to correlate with the impedance mismatching of the RF coil, which is inevitable for fixed tuning, even for automatic tuning that is not always exact. Taking into account this noise intensity, the calibration method was modified to reduce its error to 1.50%. The standard deviations of the calibrated values in the thalamus and frontal white matter were 2.9 and 3.8%, respectively. We suggest that the modified TRA method is a practical and reliable technique to obtain clinical numeric evidence.

Mesh:

Year:  2000        PMID: 11154949     DOI: 10.1007/BF02678471

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  17 in total

1.  Quantitative proton MR spectroscopic imaging of the human brain.

Authors:  B J Soher; P C van Zijl; J H Duyn; P B Barker
Journal:  Magn Reson Med       Date:  1996-03       Impact factor: 4.668

2.  A method of RF inhomogeneity correction in MR imaging.

Authors:  H Mihara; N Iriguchi; S Ueno
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

3.  Efficient remote transmission line probe tuning.

Authors:  A R Rath
Journal:  Magn Reson Med       Date:  1990-03       Impact factor: 4.668

4.  New polyvinyl alcohol gel material for MRI phantoms.

Authors:  I Mano; H Goshima; M Nambu; M Iio
Journal:  Magn Reson Med       Date:  1986-12       Impact factor: 4.668

5.  Absolute quantitative proton NMR spectroscopy based on the amplitude of the local water suppression pulse. Quantification of brain water and metabolites.

Authors:  E R Danielsen; O Henriksen
Journal:  NMR Biomed       Date:  1994-11       Impact factor: 4.044

6.  Comparison of methods for the determination of absolute metabolite concentrations in human muscles by 31P MRS.

Authors:  R Buchli; P Boesiger
Journal:  Magn Reson Med       Date:  1993-11       Impact factor: 4.668

7.  Molar quantitation of in vivo proton metabolites in human brain with 3D magnetic resonance spectroscopic imaging.

Authors:  C A Husted; J H Duijn; G B Matson; A A Maudsley; M W Weiner
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

8.  Quantification of contrast in clinical MR brain imaging at high magnetic field.

Authors:  F W Wehrli; R K Breger; J R MacFall; D L Daniels; V M Haughton; H C Charles; A L Williams
Journal:  Invest Radiol       Date:  1985-07       Impact factor: 6.016

9.  Proton NMR spectroscopy of Canavan's disease.

Authors:  P B Barker; R N Bryan; A J Kumar; S Naidu
Journal:  Neuropediatrics       Date:  1992-10       Impact factor: 1.947

10.  In vivo quantification of brain metabolites by 1H-MRS using water as an internal standard.

Authors:  P Christiansen; O Henriksen; M Stubgaard; P Gideon; H B Larsson
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.