Literature DB >> 11153582

Aerosol delivery from spacers in wheezy infants: a daily life study.

H M Janssens1, E M Heijnen, V M de Jong, W C Hop, W P Holland, J C de Jongste, H A Tiddens.   

Abstract

The aims of this study were to assess and compare dose delivery and dose variability of pressurized metered dose inhalers (pMDI)/spacers in wheezy infants in daily life and to investigate factors influencing aerosol delivery. In an open randomized crossover study in 25 wheezy infants aged 5-26 months, a metal spacer (Nebuchamber), a detergent coated (DC) and a non-detergent coated (nonDC) plastic spacer (Babyhaler) were tested at home for 7 days each. Budesonide (200 microg b.i.d) was administered via a Nebuchamber or fluticasone (125 microg b.i.d) via a Babyhaler. Aerosol was trapped in filters, positioned between the spacer and face mask. Cooperation was scored on diary cards. Electrostatic charge (ESC) of the spacers was measured. Evaluations of the administration technique were made from video recordings. Median (range) dose delivery of the filters expressed as per cent (%) of nominal dose, was 34% (3-59), 23% (1-49), and 41% (12-55) for the Nebuchamber, nonDC-Babyhaler, and DC-Babyhaler respectively. Considerable dose variability was found, median (range) within-subject dose variability, expressed as coefficient of variation, for the Nebuchamber (49% (15-249)) was significantly higher when compared with both nonDC- (36% (12-325)) and DC-Babyhalers (27% (10-122)), for which dose variabilities were similar. Detergent coating was effective to reduce electrostatic charge, and to increase dose delivery, but had no effect on dose variability. Bad cooperation was an important cause for high dose variability for all spacers (r=0.5-0.6, p<0.02). Many mistakes were made during the administration procedure.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11153582     DOI: 10.1183/09031936.00.16585000

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  6 in total

1.  Funhaler spacer: improving adherence without compromising delivery.

Authors:  P M Watt; B Clements; S G Devadason; G M Chaney
Journal:  Arch Dis Child       Date:  2003-07       Impact factor: 3.791

Review 2.  Antiasthmatic drug delivery in children.

Authors:  Elizabeth Biggart; Andrew Bush
Journal:  Paediatr Drugs       Date:  2002       Impact factor: 3.022

Review 3.  The use of inhaled corticosteroids in children with asthma.

Authors:  H William Kelly; Hengameh Heidarian-Raissy
Journal:  Curr Allergy Asthma Rep       Date:  2002-03       Impact factor: 4.806

Review 4.  Use of inhaler devices in pediatric asthma.

Authors:  Fernando Maria De Benedictis; David Selvaggio
Journal:  Paediatr Drugs       Date:  2003       Impact factor: 3.022

5.  Valved holding chamber drug delivery is dependent on breathing pattern and device design.

Authors:  Péter Csonka; Lauri Lehtimäki
Journal:  ERJ Open Res       Date:  2019-02-04

Review 6.  Optimal administration of bronchodilators with valved holding chambers in preschool children: a review of literature.

Authors:  Péter Csonka; Terhi Tapiainen; Mika J Mäkelä; Lauri Lehtimäki
Journal:  Eur J Pediatr       Date:  2021-04-20       Impact factor: 3.183

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.