| Literature DB >> 11153463 |
Abstract
Under standard conditions the left tibia was osteotomised in nine sheep. The osteotomy was transverse in six, and oblique in three. The osteotomies were fixated using a strain-gauge-monitored unilateral external fixator. The fixation was rigid in three sheep with a transverse osteotomy (group 1) and also in three sheep with an oblique osteotomy (group 2). The fixation was dynamic in three sheep with a transverse osteotomy (group 3) using a roller-bearing mechanism allowing 1 mm of axial displacement. The bone callus stiffness increased progressively with time. One month after osteotomy the load force through the fixator in groups 1 and 2 was more than 20%, whereas the equivalent load force in group 3 was only about 5%.Entities:
Mesh:
Year: 2000 PMID: 11153463 PMCID: PMC3619907 DOI: 10.1007/s002640000169
Source DB: PubMed Journal: Int Orthop ISSN: 0341-2695 Impact factor: 3.075