A total of 2,261 2-stage implants was placed in 467 patients in combination with angled abutments ranging from 0 to 45 degrees. These were observed over a period of up to 96 months, with a mean observation time of 28.8 months. Single and multiple teeth were replaced and restored using angled abutments. For patients who contributed multiple survival data, the data were considered dependent. Therefore, a mean survival estimation was performed. With a certainty of 95%, an estimated mean survival rate better than 98.6% after a 5-year observation period was calculated. The statistical comparison of 2 independent, randomized implant groups (with abutments angled between 0 and 15 degrees and between 20 and 45 degrees) by means of a log-rank test showed a probability of 0.84 (P value) that the survival functions are the same for both groups. Good esthetic and functional outcomes were observed.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11151578

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  14 in total

1.  Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

Authors:  Frank P Nothdurft; Klaus E Doppler; Kurt J Erdelt; Andreas W Knauber; Peter R Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-19       Impact factor: 3.573

2.  Replacement of a Congenitally Missing Maxillary Incisor by Implant Supported Prosthesis.

Authors:  Lakshmikanth Krishnappa; Jayakar Shetty; Vahini Reddy; Alok Shah; Sangeeta Prasad; Divya Hedge; Chiranjeevi Reddy
Journal:  J Indian Prosthodont Soc       Date:  2012-12-21

3.  Three dimensional finite element analysis of stress distribution around implant with straight and angled abutments in different bone qualities.

Authors:  G Arun Kumar; B Mahesh; Dadu George
Journal:  J Indian Prosthodont Soc       Date:  2013-01-06

4.  Assessing fit at the implant-abutment junction with a radiographic device that does not require access to the implant body.

Authors:  Kevin C Lin; Chandur P K Wadhwani; Jing Cheng; Arun Sharma; Frederick Finzen
Journal:  J Prosthet Dent       Date:  2014-05-14       Impact factor: 3.426

5.  The Single-tooth Implant Treatment of Congenitally Missing Maxillary Lateral Incisors Using Angled Abutments: A Clinical Report.

Authors:  Suleyman Hakan Tuna; Filiz Keyf; Gurel Pekkan
Journal:  Dent Res J (Isfahan)       Date:  2009

6.  A further finite element stress analysis of angled abutments for an implant placed in the anterior maxilla.

Authors:  Dong Wu; Kebin Tian; Jiang Chen; Hua Jin; Wenxiu Huang; Yuyu Liu
Journal:  Comput Math Methods Med       Date:  2015-02-23       Impact factor: 2.238

7.  The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis.

Authors:  Ebadian Behnaz; Mosharraf Ramin; Samaneh Abbasi; Memar Ardestani Pouya; Farzin Mahmood
Journal:  Eur J Dent       Date:  2015 Jul-Sep

8.  Angulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla.

Authors:  Nicholas Egbert; Swati Ahuja; Audrey Selecman; Russell Wicks
Journal:  J Dent (Shiraz)       Date:  2017-12

9.  Influence of Deformation and Stress between Bone and Implant from Various Bite Forces by Numerical Simulation Analysis.

Authors:  Hsin-Chung Cheng; Boe-Yu Peng; May-Show Chen; Chiung-Fang Huang; Yi Lin; Yung-Kang Shen
Journal:  Biomed Res Int       Date:  2017-05-28       Impact factor: 3.411

10.  Effect of different angulations and collar lengths of conical hybrid implant abutment on screw loosening after dynamic cyclic loading.

Authors:  Mai Ahmed Yousry El-Sheikh; Tamer Mohamed Nasr Mostafa; Mohamed Maamoun El-Sheikh
Journal:  Int J Implant Dent       Date:  2018-12-03