Literature DB >> 11144979

A chamber to permit invasive manipulation of adherent cells in laminar flow with minimal disturbance of the flow field.

I Levitan1, B P Helmke, P F Davies.   

Abstract

An obstacle to real-time in vitro measurements of endothelial cell responses to hemodynamic forces is the inaccessibility of the cells to instruments of measurement and manipulation. We have designed a parallel plate laminar flow chamber that permits access to adherent cells during exposure to flow. The "minimally invasive flow device" (MIF device) has longitudinal slits (1 mm wide) cut in the top plate of the chamber to allow insertion of a recording, measurement, or stimulating instrument (e.g., micropipette) into the flow field. Surface tension forces at the slit openings are sufficient to counteract the hydrostatic pressure generated in the chamber and thus prevent overflow. The invasive probe is brought near to the cell surface, makes direct contact with the cell membrane, or enters the cell. The slits provide access to a large number (and choice) of cells. The MIF device can maintain physiological levels of shear stress (<1-15 dyn/cm2) without overflow in the absence and presence of fine instruments such as micropipettes used in electrophysiology, membrane aspiration, and microinjection. Microbead trajectory profiles demonstrated negligible deviations in laminar flow near the surface of target cells in the presence of microscale instruments. Patch-clamp electrophysiological recordings of flow-induced changes in membrane potential were demonstrated. The MIF device offers numerous possibilities to investigate real-time endothelial responses to well-defined flow conditions in vitro including electrophysiology, cell surface mechanical probing, local controlled chemical release, biosensing, microinjection, and amperometric techniques.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11144979     DOI: 10.1114/1.1317529

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

Review 1.  Lung ischemia: a model for endothelial mechanotransduction.

Authors:  Shampa Chatterjee; Kenneth E Chapman; Aron B Fisher
Journal:  Cell Biochem Biophys       Date:  2008-11-04       Impact factor: 2.194

2.  Inwardly rectifying K+ channels are major contributors to flow-induced vasodilatation in resistance arteries.

Authors:  Sang Joon Ahn; Ibra S Fancher; Jing-Tan Bian; Chong Xu Zhang; Sarah Schwab; Robert Gaffin; Shane A Phillips; Irena Levitan
Journal:  J Physiol       Date:  2016-12-26       Impact factor: 5.182

3.  Cholesterol-Induced Suppression of Endothelial Kir Channels Is a Driver of Impairment of Arteriolar Flow-Induced Vasodilation in Humans.

Authors:  Sang Joon Ahn; Ibra S Fancher; Sara T Granados; Natalia F Do Couto; Chueh-Lung Hwang; Shane A Phillips; Irena Levitan
Journal:  Hypertension       Date:  2021-11-17       Impact factor: 10.190

4.  A multichannel dampened flow system for studies on shear stress-mediated mechanotransduction.

Authors:  Peter L Voyvodic; Daniel Min; Aaron B Baker
Journal:  Lab Chip       Date:  2012-07-27       Impact factor: 6.799

5.  Inward Rectifier K+ Currents Are Regulated by CaMKII in Endothelial Cells of Primarily Cultured Bovine Pulmonary Arteries.

Authors:  Lihui Qu; Lei Yu; Yanli Wang; Xin Jin; Qianlong Zhang; Ping Lu; Xiufeng Yu; Weiwei Zhong; Xiaodong Zheng; Ningren Cui; Chun Jiang; Daling Zhu
Journal:  PLoS One       Date:  2015-12-23       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.